Artifacts in photoacoustic imaging: Origins and mitigations
Photoacoustics · 2025-10 · 45 · 100745
DOI: 10.1016/j.pacs.2025.100745 ↗Kurz gefasst
Fachartikel in der Zeitschrift Photoacoustics, 2025-10. Verfasst von Max T Rietberg und 5 weiteren Autor:innen. Beteiligte Einrichtung: Multi-Modality Medical Imaging, TechMed Centre, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, Overijssel, The Netherlands. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 175 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Engineering and Physical Sciences Research Council, Kurt Weill Foundation for Music.
Abstract (Originalsprache)
Photoacoustic imaging (PAI) is rapidly moving from the laboratory to the clinic, increasing the need to understand confounders which might adversely affect patient care. Over the past five years, landmark studies have shown the clinical utility of PAI, leading to regulatory approval of several devices. In this article, we describe the various causes of artifacts in PAI, providing schematic overviews and practical examples, simulated as well as experimental. This work serves two purposes: (1) educating clinical users to identify artifacts, understand their causes, and assess their impact, and (2) providing a reference of the limitations of current systems for those working to improve them. We explain how two aspects of PAI systems lead to artifacts: their inability to measure complete data sets, and embedded assumptions during reconstruction. We describe the physics underlying PAI, and propose a classification of the artifacts. The paper concludes by discussing possible advanced mitigation strategies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Multi-Modality Medical Imaging, TechMed Centre, University of Twente, Drienerlolaan 5, Enschede, 7522 NB, Overijssel, The Netherlands.
- Cancer Research UK, Cambridge Institute, University of Cambridge, Robinson Way, Cambridge, CB2 0RE, United Kingdom.
- Department of Physics, University of Cambridge, JJ Thomson Avenue, Cambridge, CB3 0HE, United Kingdom.
- ENI-G, a Joint Initiative of the University Medical Center Göttingen and the Max Planck Institute for Multidisciplinary Sciences, Grisebachstr. 5, Göttingen, 37077, Germany.
- Department of Medical Physics and Biomedical Engineering, University College London, Gower St, London, WC1E 6BT, United Kingdom.
Förderung
- Deutsche Forschungsgemeinschaft
- Engineering and Physical Sciences Research Council
- Kurt Weill Foundation for Music
- University of Twente TechMed Centre
- Cancer Research UK
- Cancer Research UK Cambridge Research Institute
Zitieren
APA
Rietberg, M. T., Gröhl, J., Else, T. R., Bohndiek, S. E., Manohar, S., & Cox, B. T. (2025). Artifacts in photoacoustic imaging: Origins and mitigations. Photoacoustics, 45, 100745. https://doi.org/10.1016/j.pacs.2025.100745
Vancouver
Rietberg MT, Gröhl J, Else TR, Bohndiek SE, Manohar S, Cox BT. Artifacts in photoacoustic imaging: Origins and mitigations. Photoacoustics. 2025;45:100745. doi:10.1016/j.pacs.2025.100745
BibTeX
@article{Rietberg2025,
author = {Rietberg, Max T and Gröhl, Janek and Else, Thomas R and Bohndiek, Sarah E and Manohar, Srirang and Cox, Benjamin T},
title = {Artifacts in photoacoustic imaging: Origins and mitigations},
journal = {Photoacoustics},
year = {2025},
volume = {45},
pages = {100745},
doi = {10.1016/j.pacs.2025.100745}
}
EUVIMED