An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone
Photoacoustics · 2024-08 · 38 · 100604
DOI: 10.1016/j.pacs.2024.100604 ↗Kurz gefasst
Fachartikel in der Zeitschrift Photoacoustics, 2024-08. Verfasst von Jonas Pangerl und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, Regensburg 93053, Germany. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BMBF Berlin, BMWK.
Abstract (Originalsprache)
In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, Regensburg 93053, Germany.
- Institute of Analytical Chemistry, Chemo- and Biosensing, University of Regensburg, Regensburg 93053, Germany.
- Rostock Medical Breath Analytics and Technologies (RoMBAT), Dept. of Anaesthesiology, Intensive Care Medicine and Pain Therapy, University Medicine Rostock, Rostock 18057, Germany.
Förderung
- BMBF Berlin
- BMWK
Zitieren
APA
Pangerl, J., Sukul, P., Rück, T., Fuchs, P., Weigl, S., Miekisch, W., Bierl, R., & Matysik, F. M. (2024). An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone. Photoacoustics, 38, 100604. https://doi.org/10.1016/j.pacs.2024.100604
Vancouver
Pangerl J, Sukul P, Rück T, Fuchs P, Weigl S, Miekisch W, et al. An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone. Photoacoustics. 2024;38:100604. doi:10.1016/j.pacs.2024.100604
BibTeX
@article{Pangerl2024,
author = {Pangerl, Jonas and Sukul, Pritam and Rück, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael},
title = {An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone},
journal = {Photoacoustics},
year = {2024},
volume = {38},
pages = {100604},
doi = {10.1016/j.pacs.2024.100604}
}
EUVIMED