Fachartikel in der Zeitschrift Orthopaedics & Traumatology: Surgery & Research, 2026-03. Verfasst von Jong-Hyub Song und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND The purpose was to investigate the differences in distal femoral rotational angles between CT and MRI scans. METHODS This study included 195 patients who underwent primary total knee arthroplasty (TKA) for medial osteoarthritis with varus knee. The angle between the surgical transepicondylar axis (sTEA) and the posterior condylar line (PCL) was the posterior condylar angle (PCA), and the angle between the clinical transepicondylar axis (cTEA) and PCL was the condylar twist angle (CTA). CT (CT PCA, CT CTA) and MRI (MR PCA, MR CTA) measures of these values were compared. The thicknesses of the posterior medial and lateral femoral condylar cartilages were measured using MRI. RESULTS The PCA and CTA were 1.5-1.6 ° smaller on MRI than on CT. The posterior medial femoral condylar (MFC) cartilage was 0.8 mm thinner than the posterior lateral femoral condylar (LFC) cartilage on MRI. Posterior MFC cartilage thickness showed negative correlations with the CT-MR PCA (r=-0.366, P < 0.001) and CT-MR CTA (r=-0.383, P < 0.001), respectively. Multiple regression analysis revealed that MR PCA and posterior MFC cartilage thickness were predictors of CT-MR PCA and CT-MR CTA. The optimum cutoff values of posterior MFC cartilage thickness for greater than 1° of CT-MR PCA and CT-MR CTA were of 1.16 mm (60.94% sensitivity, 77.61% specificity, P < 0.001) and 1.09 mm (55.6% sensitivity, 75.4% specificity, P < 0.001). CONCLUSION The PCA and CTA on MRI were 1.5-1.6 ° smaller than those on CT in varus osteoarthritic knees because of posteromedial femoral cartilage wear, suggesting that MRI could be a better evaluation tool for measuring distal femoral rotational profiles as it accurately reflects the cartilage thickness of the posteromedial and posterolateral femoral condyles. LEVEL OF EVIDENCE IV; case series.

Schlagwörter

Stichwörter der Autor:innen

Component rotationCoronal alignmentFemoral componentFemoral component rotational alignmentHip knee ankle angleRotational alignment

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Department of Orthopedic Surgery, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Electronic address: eoak22@empal.com.

Zitieren

APA

Song, J. H., Lee, S. S., & Lee, D. H. (2026). Measurement of distal femoral rotational angles in varus knee osteoarthritis: a comparison between CT and MRI. Orthopaedics & Traumatology: Surgery & Research, 104647. https://doi.org/10.1016/j.otsr.2026.104647

Vancouver

Song JH, Lee SS, Lee DH. Measurement of distal femoral rotational angles in varus knee osteoarthritis: a comparison between CT and MRI. Orthopaedics & Traumatology: Surgery & Research. 2026:104647. doi:10.1016/j.otsr.2026.104647

BibTeX
@article{Song2026,
  author = {Song, Jong-Hyub and Lee, Sung-Sahn and Lee, Dae-Hee},
  title = {Measurement of distal femoral rotational angles in varus knee osteoarthritis: a comparison between CT and MRI},
  journal = {Orthopaedics & Traumatology: Surgery & Research},
  year = {2026},
  pages = {104647},
  doi = {10.1016/j.otsr.2026.104647}
}
Kostenlos starten →