EUVIMEDEUVIMED entdecken
Vergleichsstudie

Intraoral tomosynthesis accuracy for cone length measurement is comparable to physical measurement of gutta-percha

Jenni Olson, Archna Nagpal, Reid Loveless, Aniuska Tobin, Aditya Tadinada

Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology · 2027-01 · 143 (1) · 107-114

DOI: 10.1016/j.oooo.2026.06.024 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2027-01. Verfasst von Jenni Olson und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, UConn Health, Farmington, CT, USA. Electronic address: jeolson@uchc.edu. Hauptthemen laut MEDLINE: Gutta-Percha, Root Canal Filling Materials, Cone-Beam Computed Tomography, Dental Pulp Cavity. Die Arbeit nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To assess the efficacy of cone fit measurements of digital periapical (PA) and stationary intraoral tomosynthesis (s-IOT) images and compare them to the physical measurement of gutta-percha (gold standard). STUDY DESIGN Images of 40 extracted teeth with gutta-percha in their prepared root canals were acquired using digital PA and 3D s-IOT devices (Portray system), while the physical cone length of the gutta-percha was measured using a digital vernier caliper. Digital PA cone length was measured using MiPACS Dental Enterprise Viewer Software with a polyline measurement tool. Cone length in the s-IOT images was measured by scrolling through synthetic images taken at different angle disparities. All measurements were recorded and subjected to statistical analysis. RESULTS Interclass correlation coefficient (ICC) test showed statistical significance. The gold standard vs s-IOT measurements had the highest reliability across all groups, often exceeding 0.9. Comparisons involving PA (PA vs gold standard and PA vs s-IOT) tend to have lower reliability, with several confidence intervals including 0. Statistically significant P-values across all comparisons suggest these ICCs are meaningful, but confidence intervals highlight potential issues with data variability. CONCLUSIONS While both modalities differed from the gold standard, s-IOT demonstrated a clear advantage in measurement accuracy and reliability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gutta-PerchaRoot Canal Filling MaterialsCone-Beam Computed TomographyDental Pulp CavityRadiography, Dental, DigitalHumansReproducibility of ResultsImaging, Three-Dimensional

Substanzen

Gutta-PerchaRoot Canal Filling Materials

Autor:innen und Institutionen

  • Department of Endodontics, UConn Health, Farmington, CT, USA. Electronic address: jeolson@uchc.edu.
  • School of Dental Medicine, Pacific Northwest University of Health Sciences, Yakima, WA, USA.
  • Dental College of Georgia, Augusta University, Augusta, GA, USA.
  • Department of Endodontics, UConn Health, Farmington, CT, USA.
  • Department of Oral and Maxillofacial Radiology, UConn Health, Farmington, CT, USA.

Zitieren

APA

Olson, J., Nagpal, A., Loveless, R., Tobin, A., & Tadinada, A. (2027). Intraoral tomosynthesis accuracy for cone length measurement is comparable to physical measurement of gutta-percha. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 143(1), 107-114. https://doi.org/10.1016/j.oooo.2026.06.024

Vancouver

Olson J, Nagpal A, Loveless R, Tobin A, Tadinada A. Intraoral tomosynthesis accuracy for cone length measurement is comparable to physical measurement of gutta-percha. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. 2027;143(1):107-114. doi:10.1016/j.oooo.2026.06.024

BibTeX
@article{Olson2027,
  author = {Olson, Jenni and Nagpal, Archna and Loveless, Reid and Tobin, Aniuska and Tadinada, Aditya},
  title = {Intraoral tomosynthesis accuracy for cone length measurement is comparable to physical measurement of gutta-percha},
  journal = {Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology},
  year = {2027},
  volume = {143},
  number = {1},
  pages = {107--114},
  doi = {10.1016/j.oooo.2026.06.024}
}
Kostenlos starten →