EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development

Thomas M Leibiger, Luke A Remmler, Erica A Green, Kelvin H Lee

Molecular Therapy - Methods & Clinical Development · 2024-09 · 32 (3) · 101306

DOI: 10.1016/j.omtm.2024.101306 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecular Therapy - Methods & Clinical Development, 2024-09. Verfasst von Thomas M Leibiger und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Delaware, Department of Chemical and Biomolecular Engineering, Newark, DE, USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: U.S. Department of Commerce, NIST.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Faster and more accurate analytical methods are needed to support the advancement of recombinant adeno-associated virus (rAAV) production systems. Recently, biolayer interferometry (BLI) has been developed for high-throughput AAV capsid titer measurement by functionalizing the AAVX ligand onto biosensor probes (AAVX-BLI). In this work, an AAVX-BLI method was evaluated using Octet AAVX biosensors across four rAAV serotypes (rAAV2, -5, -8, and -9) and applied in an upstream and downstream processing context. AAVX-BLI measured the capsid titer across a wide concentration range (1 × 1010-1 × 1012 capsids/mL) for different rAAV serotypes and sample backgrounds with reduced measurement variance and error compared to an enzyme-linked immunosorbent assay (ELISA) method. Biosensors were regenerated for repeated use, with lysate samples showing reduced regeneration capacity compared to purified and supernatant samples. The AAVX-BLI method was applied in a transfection optimization study where direct capsid titer measurement of culture supernatants generated a representative response surface for the total vector genome (VG) titer. For rAAV purification, AAVX-BLI was used to measure dynamic binding capacity with POROS CaptureSelect AAVX affinity chromatography, showing resin breakthrough dependence on the operating flow rate. Measurement accuracy, serotype and sample background flexibility, and high sample throughput make AAVX-BLI an attractive alternative to other capsid titer measurement techniques.

Schlagwörter

Stichwörter der Autor:innen

AAVAAVXBLIadeno-associated virusbiolayer interferometrycapsid titerdynamic binding capacityprocess developmenttransfection optimizationvector genome titer

Autor:innen und Institutionen

  • University of Delaware, Department of Chemical and Biomolecular Engineering, Newark, DE, USA.

Förderung

  • U.S. Department of Commerce
  • NIST

Zitieren

APA

Leibiger, T. M., Remmler, L. A., Green, E. A., & Lee, K. H. (2024). Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development. Molecular Therapy - Methods & Clinical Development, 32(3), 101306. https://doi.org/10.1016/j.omtm.2024.101306

Vancouver

Leibiger TM, Remmler LA, Green EA, Lee KH. Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development. Molecular Therapy - Methods & Clinical Development. 2024;32(3):101306. doi:10.1016/j.omtm.2024.101306

BibTeX
@article{Leibiger2024,
  author = {Leibiger, Thomas M and Remmler, Luke A and Green, Erica A and Lee, Kelvin H},
  title = {Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development},
  journal = {Molecular Therapy - Methods & Clinical Development},
  year = {2024},
  volume = {32},
  number = {3},
  pages = {101306},
  doi = {10.1016/j.omtm.2024.101306}
}
Kostenlos starten →