EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Adeno-associated viral capsid stability on anion exchange chromatography column and its impact on empty and full capsid separation

Ohnmar Khanal, Vijesh Kumar, Mi Jin

Molecular Therapy Methods & Clinical Development · 2023-12 · 31 · 101112

DOI: 10.1016/j.omtm.2023.101112 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecular Therapy Methods & Clinical Development, 2023-12. Verfasst von Ohnmar Khanal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Technology Development, Spark Therapeutics, Inc., Philadelphia, PA, USA. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recombinant adeno-associated viral vector (rAAV) mediated gene therapy is gaining traction in treating genetic disorders. Current rAAV production systems yield a mixture of capsids largely devoid of the transgene (empty capsid) compared with the desired therapeutic product (full capsid). Anion exchange chromatography (AEX) is an attractive method for separating empty and full AAV capsids because of its scalability. Resin types and buffer composition are key considerations for AEX and must support capsid stability to be suitable for downstream processing. We examined the impact of binding durations (0-8 h) using various binding ionic strengths (15-75 mM), pH (7.5-9.0), resin chemistry (POROS XQ, POROS HQ, POROS I, and BIA QA monolith), and proprietary Q resins with different ligand densities for effects on capsid stability. Empty capsids were altered upon extended binding, leading to retention time shifts and loss of resolution between empty and full capsids. Viral capsid protein analysis reveals that full capsids have more viral capsid protein 3 (VP3) proteins than empty capsids. Analytical hydrophilic liquid chromatography showed that empty capsid retention time shift is accompanied by changes to the empty capsid's native VP3 protein. Among the potential stabilizing additives considered, magnesium chloride was the most effective at reducing negative impacts caused by extended binding.

Schlagwörter

Stichwörter der Autor:innen

AAV stabilityAEXanalytical hydrophilic interaction liquid chromatographyanion exchange chromatographyempty capsidsfull capsidsstability in adsorbed stateviral capsid proteins

Autor:innen und Institutionen

  • Technology Development, Spark Therapeutics, Inc., Philadelphia, PA, USA.

Zitieren

APA

Khanal, O., Kumar, V., & Jin, M. (2023). Adeno-associated viral capsid stability on anion exchange chromatography column and its impact on empty and full capsid separation. Molecular Therapy Methods & Clinical Development, 31, 101112. https://doi.org/10.1016/j.omtm.2023.101112

Vancouver

Khanal O, Kumar V, Jin M. Adeno-associated viral capsid stability on anion exchange chromatography column and its impact on empty and full capsid separation. Molecular Therapy Methods & Clinical Development. 2023;31:101112. doi:10.1016/j.omtm.2023.101112

BibTeX
@article{Khanal2023,
  author = {Khanal, Ohnmar and Kumar, Vijesh and Jin, Mi},
  title = {Adeno-associated viral capsid stability on anion exchange chromatography column and its impact on empty and full capsid separation},
  journal = {Molecular Therapy Methods & Clinical Development},
  year = {2023},
  volume = {31},
  pages = {101112},
  doi = {10.1016/j.omtm.2023.101112}
}
Kostenlos starten →