On the Feasibility of Accelerating Glaucoma Clinical Trials Using Portable Perimetry

Jeremy C K Tan, Giovanni Montesano, Jonathan Crowston, Katharina Bell, David P Crabb, Pete R Jones

Ophthalmology Glaucoma · 2026

DOI: 10.1016/j.ogla.2025.08.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmology Glaucoma, 2026. Verfasst von Jeremy C K Tan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Visual Sciences, School of Health & Medical Sciences, City St George's, University of London, London, England; Save Sight…. Hauptthemen laut MEDLINE: Visual Field Tests, Visual Fields, Glaucoma, Intraocular Pressure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: UK Research and Innovation, Vivensa Foundation, Astellas Pharma US.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To model whether more frequent (weekly, monthly) visual field (VF) assessments using portable "home" perimetry might more quickly detect glaucoma progression in a clinical trial context. DESIGN: Cross-sectional with additional simulations PARTICIPANTS: Forty patients (78 eyes; n = 21 healthy, n = 16 glaucoma suspects, n = 41 manifest glaucoma). METHODS: Participants performed an interleaved sequence of 2 portable (Eyecatcher v3.0; EC3) and 2 reference (Humphrey Field Analzyer [HFA] SITA-Fast) VF tests (4 tests total per eye). Linear mixed modeling was then applied to one randomly selected eye per patient to mathematically predict the expected proportion of progressors detected by EC3/HFA over a 3-year period, given different testing regimens (from weekly to every 4 months), levels of variability, and underlying rates of true progression. MAIN OUTCOME MEASURES: Test-retest variability and proportion of progressors detected. RESULTS: The portable perimeter was significantly less reliable: the Bland-Altman 95% coefficient of repeatability for mean deviation (CoRMD95%) was 6.37 dB for EC3 and 4.25 dB for the HFA. Statistical simulations, however, predicted that this lower reliability would be offset by more frequent testing. Thus, modeling indicated one EC3 test per month would detect a higher proportion of slow (-0.5 dB/year), moderate (-1 dB/year), and fast (-2 dB/year) progressors compared to one HFA test every 4 months. Implications for trial sample sizes were also modeled, with the number of participants required to evidence a 20% reduction in baseline progression over 2 years (following a hypothetical intervention) predicted to decrease by 24.3%/36.3% with the addition of monthly/fortnightly home testing. There was no significant difference in mean test duration between the EC3 and HFA (226 vs. 225 seconds, P = 0.78), and participants rated the EC3 as somewhat easier to use (system usability scale; P = 0.004). CONCLUSIONS: Home VF assessments, despite poorer reliability than current reference standard ("in-clinic") devices, would allow faster or greater detection of glaucoma progression via an increased frequency of testing, and could reduce the sample size requirements of future clinical trials. Implications on duration, access and overall cost are discussed. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual Field TestsVisual FieldsGlaucomaIntraocular PressureClinical Trials as TopicHumansCross-Sectional StudiesMaleFemaleMiddle AgedDisease ProgressionFeasibility StudiesReproducibility of ResultsAged

Stichwörter der Autor:innen

Clinical trialsGlaucomaHome monitoringTelemedicineVisual fields

Autor:innen und Institutionen

  • Department of Optometry and Visual Sciences, School of Health & Medical Sciences, City St George's, University of London, London, England; Save Sight Institute, University of Sydney, Camperdown, New South Wales, Austral…
  • Department of Optometry and Visual Sciences, School of Health & Medical Sciences, City St George's, University of London, London, England.
  • Save Sight Institute, University of Sydney, Camperdown, New South Wales, Australia; Singapore Eye Research Institute and Duke-NUS, Singapore.
  • NHMRC Clinical Trials Centre, University of Sydney, Camperdown, New South Wales, Australia.

Förderung

  • UK Research and Innovation
  • Vivensa Foundation
  • Astellas Pharma US
  • UK Research and Innovation Economic and Social Research Council

Zitieren

APA

Tan, J. C. K., Montesano, G., Crowston, J., Bell, K., Crabb, D. P., & Jones, P. R. (2026). On the Feasibility of Accelerating Glaucoma Clinical Trials Using Portable Perimetry. Ophthalmology Glaucoma. https://doi.org/10.1016/j.ogla.2025.08.004

Vancouver

Tan JCK, Montesano G, Crowston J, Bell K, Crabb DP, Jones PR. On the Feasibility of Accelerating Glaucoma Clinical Trials Using Portable Perimetry. Ophthalmology Glaucoma. 2026. doi:10.1016/j.ogla.2025.08.004

BibTeX
@article{Tan2026,
  author = {Tan, Jeremy C K and Montesano, Giovanni and Crowston, Jonathan and Bell, Katharina and Crabb, David P and Jones, Pete R},
  title = {On the Feasibility of Accelerating Glaucoma Clinical Trials Using Portable Perimetry},
  journal = {Ophthalmology Glaucoma},
  year = {2026},
  doi = {10.1016/j.ogla.2025.08.004}
}
Kostenlos starten →