Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants
Nutrition, Metabolism and Cardiovascular Diseases · 2026
DOI: 10.1016/j.numecd.2026.104715 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Nutrition, Metabolism and Cardiovascular Diseases, 2026. Verfasst von Shaohua Yan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Bei…. Hauptthemen laut MEDLINE: Exercise, Actigraphy, Fitness Trackers, Risk Reduction Behavior. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: China Academy of Chinese Medical Sciences Institute of Chinese Materia Medica, Chinese Academy of Medical Sciences, National Science and Technology Major Project.
Abstract (Originalsprache)
BACKGROUND AND AIM: Aortic aneurysm (AA) is a life-threatening vascular disease with high fatality upon rupture. While physical activity (PA) reduces cardiovascular risk, its role in AA prevention remains uncertain, particularly when assessed objectively. METHODS AND RESULTS: We analyzed 93,165 UK Biobank participants (56% women; median age 57 years) with valid 7-day wrist-worn accelerometer data. PA was categorized as light (LPA), moderate (MPA), vigorous (VPA), and moderate-to-vigorous (MVPA). Diagnosed AA was ascertained through linked hospital, death, and primary care records. Cox models estimated hazard ratios (HRs) for AA across quartiles and per-standard deviation (SD) increments, with adjustment for demographic, lifestyle, and cardiometabolic factors. Over a median 7.9-year follow-up, 499 clinically recorded AA cases occurred. Higher accelerometer-measured PA was inversely associated with AA risk. Per-SD increments in total PA, MPA, VPA, and MVPA corresponded to 17%, 22%, 19%, and 23% lower risks, respectively. Compared with the lowest quartile, the highest MVPA quartile had a 44% lower AA risk (HR = 0.56, 95% CI 0.42-0.76). Subtype analyses revealed stronger protective effects for abdominal aortic aneurysm (AAA) than thoracic aortic aneurysm (TAA), while LPA was not significantly associated. CONCLUSIONS: These findings demonstrate that higher levels of accelerometer-measured MVPA are robustly associated with a decreased risk of clinically detected AA in a dose-dependent manner. The associations were particularly pronounced for AAA. This study provides objective evidence supporting the potential benefits of MVPA for aortic health.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, 10000, China; Beijing Hospital, National Center of Gerontology,…
- Department of General Surgery, The Third Xiangya Hospital, Central South University, 138# Tongzipo Road, Changsha, 410013, China.
- Department of Breast Surgery, The Eighth Affiliated Hospital of Sun Yat-sen University, 3025# Shennan Road, Shenzhen, 518000, China.
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China. Electronic address: jsy19990219@163.com.
- Department of Chemical Pathology, Li Ka Shing Institute of Health Science, Faulty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China. Electronic address: youngphone6236@163.com.
Förderung
- China Academy of Chinese Medical Sciences Institute of Chinese Materia Medica
- Chinese Academy of Medical Sciences
- National Science and Technology Major Project
Zitieren
APA
Yan, S., Zhu, C., Hu, Y., Guo, W., Liu, Y., Wang, T., Jin, S., Hou, Y., & Wang, H. (2026). Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants. Nutrition, Metabolism and Cardiovascular Diseases. https://doi.org/10.1016/j.numecd.2026.104715
Vancouver
Yan S, Zhu C, Hu Y, Guo W, Liu Y, Wang T, et al. Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants. Nutrition, Metabolism and Cardiovascular Diseases. 2026. doi:10.1016/j.numecd.2026.104715
BibTeX
@article{Yan2026,
author = {Yan, Shaohua and Zhu, Changyan and Hu, Yuqiu and Guo, Wei and Liu, Yujia and Wang, Ting and Jin, Shuyu and Hou, Yangfeng and Wang, Hua},
title = {Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants},
journal = {Nutrition, Metabolism and Cardiovascular Diseases},
year = {2026},
doi = {10.1016/j.numecd.2026.104715}
}
EUVIMED