EUVIMEDEUVIMED entdecken
Kohortenstudie

Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants

Shaohua Yan, Changyan Zhu, Yuqiu Hu, Wei Guo, Yujia Liu, Ting Wang, Shuyu Jin, Yangfeng Hou, Hua Wang

Nutrition, Metabolism and Cardiovascular Diseases · 2026

DOI: 10.1016/j.numecd.2026.104715 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Nutrition, Metabolism and Cardiovascular Diseases, 2026. Verfasst von Shaohua Yan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Bei…. Hauptthemen laut MEDLINE: Exercise, Actigraphy, Fitness Trackers, Risk Reduction Behavior. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: China Academy of Chinese Medical Sciences Institute of Chinese Materia Medica, Chinese Academy of Medical Sciences, National Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND AIM: Aortic aneurysm (AA) is a life-threatening vascular disease with high fatality upon rupture. While physical activity (PA) reduces cardiovascular risk, its role in AA prevention remains uncertain, particularly when assessed objectively. METHODS AND RESULTS: We analyzed 93,165 UK Biobank participants (56% women; median age 57 years) with valid 7-day wrist-worn accelerometer data. PA was categorized as light (LPA), moderate (MPA), vigorous (VPA), and moderate-to-vigorous (MVPA). Diagnosed AA was ascertained through linked hospital, death, and primary care records. Cox models estimated hazard ratios (HRs) for AA across quartiles and per-standard deviation (SD) increments, with adjustment for demographic, lifestyle, and cardiometabolic factors. Over a median 7.9-year follow-up, 499 clinically recorded AA cases occurred. Higher accelerometer-measured PA was inversely associated with AA risk. Per-SD increments in total PA, MPA, VPA, and MVPA corresponded to 17%, 22%, 19%, and 23% lower risks, respectively. Compared with the lowest quartile, the highest MVPA quartile had a 44% lower AA risk (HR = 0.56, 95% CI 0.42-0.76). Subtype analyses revealed stronger protective effects for abdominal aortic aneurysm (AAA) than thoracic aortic aneurysm (TAA), while LPA was not significantly associated. CONCLUSIONS: These findings demonstrate that higher levels of accelerometer-measured MVPA are robustly associated with a decreased risk of clinically detected AA in a dose-dependent manner. The associations were particularly pronounced for AAA. This study provides objective evidence supporting the potential benefits of MVPA for aortic health.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExerciseActigraphyFitness TrackersRisk Reduction BehaviorAortic AneurysmHumansFemaleMaleMiddle AgedProspective StudiesAgedUnited KingdomRisk AssessmentUK BiobankTime FactorsProtective FactorsRisk FactorsBiological Specimen BanksAdultPredictive Value of Tests

Stichwörter der Autor:innen

Abdominal aortic aneurysmAccelerometerAortic aneurysmPhysical activityThoracic aortic aneurysmUK Biobank

Autor:innen und Institutionen

  • Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, 10000, China; Beijing Hospital, National Center of Gerontology,…
  • Department of General Surgery, The Third Xiangya Hospital, Central South University, 138# Tongzipo Road, Changsha, 410013, China.
  • Department of Breast Surgery, The Eighth Affiliated Hospital of Sun Yat-sen University, 3025# Shennan Road, Shenzhen, 518000, China.
  • Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China. Electronic address: jsy19990219@163.com.
  • Department of Chemical Pathology, Li Ka Shing Institute of Health Science, Faulty of Medicine, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China. Electronic address: youngphone6236@163.com.

Förderung

  • China Academy of Chinese Medical Sciences Institute of Chinese Materia Medica
  • Chinese Academy of Medical Sciences
  • National Science and Technology Major Project

Zitieren

APA

Yan, S., Zhu, C., Hu, Y., Guo, W., Liu, Y., Wang, T., Jin, S., Hou, Y., & Wang, H. (2026). Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants. Nutrition, Metabolism and Cardiovascular Diseases. https://doi.org/10.1016/j.numecd.2026.104715

Vancouver

Yan S, Zhu C, Hu Y, Guo W, Liu Y, Wang T, et al. Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants. Nutrition, Metabolism and Cardiovascular Diseases. 2026. doi:10.1016/j.numecd.2026.104715

BibTeX
@article{Yan2026,
  author = {Yan, Shaohua and Zhu, Changyan and Hu, Yuqiu and Guo, Wei and Liu, Yujia and Wang, Ting and Jin, Shuyu and Hou, Yangfeng and Wang, Hua},
  title = {Association between device-measured physical activity and aortic aneurysm risk: a prospective cohort study of 93165 UK biobank participants},
  journal = {Nutrition, Metabolism and Cardiovascular Diseases},
  year = {2026},
  doi = {10.1016/j.numecd.2026.104715}
}
Kostenlos starten →