DEMAND: An organic glass scintillator array for direct measurements of (α,n) and (p,n) reactions in inverse kinematics

G. Christian, B.J. Reed, G. Lotay, G. Bartram, S. Blackmore, D.T. Doherty, A. Katrusiak, J. Henderson, D.A. Hutcheon, A. Lennarz, M. Loria, J. O’Neill und 5 weitere

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2027-03 · 1095 · 172211

DOI: 10.1016/j.nima.2026.172211 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2027-03. Verfasst von G. Christian und 16 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Science and Technology Facilities Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We have developed an array of up to 20 organic glass scintillator detectors, each consisting of a $3~\mathrm{cm}\times3~\mathrm{cm}\times3~\mathrm{cm}$ scintillator cube coupled to a photomultiplier tube. Sensitive to neutrons from a few hundred keV to several tens of MeV, the array was designed for use with recoil separators in inverse-kinematics measurements of astrophysical $(\alpha,n)$ and $(p,n)$ reactions. It provides a prompt start signal for identifying recoil-neutron coincidences from the recoil time of flight. We characterize eight detectors used in an inverse-kinematics measurement of $^{22}\mathrm{Ne}(\alpha,n)^{25}\mathrm{Mg}$, using source and in-beam data. From the widths of $\gamma$-ray Compton-edge peaks at 311, 341, 477, and 1062 keVee, we find an energy resolution described by $\mathrm{FWHM}(E)/E=\sqrt{A^2/E+B^2/E^2+C^2}$, with $A=0.00(7)$, $B=0.0618(54)$, and $C=0.135(5)$. The time-difference spectrum of nearest-neighbor $\gamma$-$\gamma$ coincidences from a $^{22}\mathrm{Na}$ source (250--600 keVee) gives a FWHM coincidence timing resolution of $910(40)$ ps, corresponding to a single-detector resolution of $640(30)$ ps. Mixed neutron-$\gamma$ fields from the in-beam reaction and a $^{241}\mathrm{AmBe}$ source show pulse-shape discrimination with an $n$-$\gamma$ figure of merit $>1$ down to about 100 keVee. Below 100 keVee, the total neutron yield can still be extracted using two-Gaussian fits to energy-gated pulse-shape discrimination spectra. Monte Carlo simulations of the present $^{22}\mathrm{Ne}(\alpha,n)^{25}\mathrm{Mg}$ measurement give a neutron singles detection efficiency of $1.56(45)%$, with uncertainty dominated by systematic effects in the simulation inputs.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Science and Technology Facilities Council

Zitieren

APA

Christian, G., Reed, B., Lotay, G., Bartram, G., Blackmore, S., Doherty, D., Katrusiak, A., Henderson, J., Hutcheon, D., Lennarz, A., Loria, M., O’Neill, J., O’Shea, C., Paxman, C., Ruiz, C., Wagner, L., & Williams, M. (2027). DEMAND: An organic glass scintillator array for direct measurements of (α,n) and (p,n) reactions in inverse kinematics. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1095, 172211. https://doi.org/10.1016/j.nima.2026.172211

Vancouver

Christian G, Reed B, Lotay G, Bartram G, Blackmore S, Doherty D, et al. DEMAND: An organic glass scintillator array for direct measurements of (α,n) and (p,n) reactions in inverse kinematics. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2027;1095:172211. doi:10.1016/j.nima.2026.172211

BibTeX
@article{Christian2027,
  author = {Christian, G. and Reed, B.J. and Lotay, G. and Bartram, G. and Blackmore, S. and Doherty, D.T. and Katrusiak, A. and Henderson, J. and Hutcheon, D.A. and Lennarz, A. and Loria, M. and O’Neill, J. and O’Shea, C. and Paxman, C.J. and Ruiz, C. and Wagner, L. and Williams, M.},
  title = {DEMAND: An organic glass scintillator array for direct measurements of (α,n) and (p,n) reactions in inverse kinematics},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2027},
  volume = {1095},
  pages = {172211},
  doi = {10.1016/j.nima.2026.172211}
}
Kostenlos starten →