EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Charge-carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Faiz Rahman Ishaqzai, Muhammed Deniz, Marta Baselga Bacardit, Tobias Bisanz, Kevin Kröninger, Jens Weingarten, Antonia Wippermann

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2027-02 · 1094 · 172164

DOI: 10.1016/j.nima.2026.172164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2027-02. Verfasst von Faiz Rahman Ishaqzai und 6 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alexander von Humboldt Foundation, DFG.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

Förderung

  • Alexander von Humboldt Foundation
  • DFG

Zitieren

APA

Ishaqzai, F. R., Deniz, M., Bacardit, M. B., Bisanz, T., Kröninger, K., Weingarten, J., & Wippermann, A. (2027). Charge-carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1094, 172164. https://doi.org/10.1016/j.nima.2026.172164

Vancouver

Ishaqzai FR, Deniz M, Bacardit MB, Bisanz T, Kröninger K, Weingarten J, et al. Charge-carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2027;1094:172164. doi:10.1016/j.nima.2026.172164

BibTeX
@article{Ishaqzai2027,
  author = {Ishaqzai, Faiz Rahman and Deniz, Muhammed and Bacardit, Marta Baselga and Bisanz, Tobias and Kröninger, Kevin and Weingarten, Jens and Wippermann, Antonia},
  title = {Charge-carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2027},
  volume = {1094},
  pages = {172164},
  doi = {10.1016/j.nima.2026.172164}
}
Kostenlos starten →