EUVIMEDEUVIMED entdecken
Crossref

Application and optimization of the GET electronics system for double-sided silicon strip detector readout

Jiawei Bian, Zaihong Yang, Qite Li, Zeyu Du, Xuan Wang, Ningtao Zhang, Pengjie Li, Zhongtao Shen, Kaijie Zhou, Cheng Wang

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-11 · 1091 · 171772

DOI: 10.1016/j.nima.2026.171772 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-11. Verfasst von Jiawei Bian und 9 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: State Key Laboratory of Nuclear Physics and Technology, Peking University, National Natural Science Foundation of China, National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Double-sided silicon strip detectors (DSSDs) are widely used for charged-particle detection in nuclear reaction experiments. However, the large number of readout channels associated with DSSDs places stringent demands on front-end electronics and data acquisition systems, particularly in experiments employing large detector arrays. In this work, we investigate the application and optimization of the Generic Electronics for Time Projection Chambers (GET) system for multi-channel DSSD readout. Through optimization of the DC-blocking capacitors on the custom-designed interface board and waveform-based energy extraction algorithms, the readout system achieves an energy resolution of {\sigma} = 22 keV for 5.49 MeV alpha particles. Its performance is further validated in a representative nuclear physics experiment employing charged-particle telescopes. The results demonstrate that the GET system provides a versatile and scalable waveform-sampling solution for multi-channel DSSD readout.

Förderung

  • State Key Laboratory of Nuclear Physics and Technology, Peking University
  • National Natural Science Foundation of China
  • National Key Research and Development Program of China

Zitieren

APA

Bian, J., Yang, Z., Li, Q., Du, Z., Wang, X., Zhang, N., Li, P., Shen, Z., Zhou, K., & Wang, C. (2026). Application and optimization of the GET electronics system for double-sided silicon strip detector readout. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1091, 171772. https://doi.org/10.1016/j.nima.2026.171772

Vancouver

Bian J, Yang Z, Li Q, Du Z, Wang X, Zhang N, et al. Application and optimization of the GET electronics system for double-sided silicon strip detector readout. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1091:171772. doi:10.1016/j.nima.2026.171772

BibTeX
@article{Bian2026,
  author = {Bian, Jiawei and Yang, Zaihong and Li, Qite and Du, Zeyu and Wang, Xuan and Zhang, Ningtao and Li, Pengjie and Shen, Zhongtao and Zhou, Kaijie and Wang, Cheng},
  title = {Application and optimization of the GET electronics system for double-sided silicon strip detector readout},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2026},
  volume = {1091},
  pages = {171772},
  doi = {10.1016/j.nima.2026.171772}
}
Kostenlos starten →