EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

K. Adamczyk, H. Aihara, K. Amos, S. Bacher, S. Bahinipati, J. Baudot, P.K. Behera, S. Bettarini, A. Bozek, F. Buchsteiner, G. Casarosa, C. Cheshta und 28 weitere

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-11 · 1091 · 171683

DOI: 10.1016/j.nima.2026.171683 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-11. Verfasst von K. Adamczyk und 39 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Istituto Nazionale di Fisica Nucleare, Ministry of Education, Culture, Sports, Science and Technology, Horizon 2020 Marie Skłodowska-Curie Actions.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

Förderung

  • Istituto Nazionale di Fisica Nucleare
  • Ministry of Education, Culture, Sports, Science and Technology
  • Horizon 2020 Marie Skłodowska-Curie Actions
  • Horizon 2020 European Innovation Council Fast Track to Innovation
  • Rudi Schulte Research Institute
  • Ministerstwo Edukacji i Nauki
  • European Research Council
  • Japan Society for the Promotion of Science

Zitieren

APA

Adamczyk, K., Aihara, H., Amos, K., Bacher, S., Bahinipati, S., Baudot, J., Behera, P., Bettarini, S., Bozek, A., Buchsteiner, F., Casarosa, G., Cheshta, C., Corona, L., Das, S., Dujany, G., Finck, C., Forti, F., Friedl, M., Gabrielli, A., …, & Raj, V. (2026). Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1091, 171683. https://doi.org/10.1016/j.nima.2026.171683

Vancouver

Adamczyk K, Aihara H, Amos K, Bacher S, Bahinipati S, Baudot J, et al. Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1091:171683. doi:10.1016/j.nima.2026.171683

BibTeX
@article{Adamczyk2026,
  author = {Adamczyk, K. and Aihara, H. and Amos, K. and Bacher, S. and Bahinipati, S. and Baudot, J. and Behera, P.K. and Bettarini, S. and Bozek, A. and Buchsteiner, F. and Casarosa, G. and Cheshta, C. and Corona, L. and Das, S.B. and Dujany, G. and Finck, C. and Forti, F. and Friedl, M. and Gabrielli, A. and Gautam, V. and Gobbo, B. and Hara, K. and Higuchi, T. and Irmler, C. and Ishikawa, A. and Kaleta, M. and Kaliyar, A.B. and Kang, K.H. and Kumar, R. and Lalwani, K. and Libby, J. and Lisovskyi, V. and Massaccesi, L. and Mohanty, G.B. and Nakamura, K.R. and Natkaniec, Z. and Onuki, Y. and Otani, F. and Paladino, A. and Raj, V.},
  title = {Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2026},
  volume = {1091},
  pages = {171683},
  doi = {10.1016/j.nima.2026.171683}
}
Kostenlos starten →