Performance of the LHCb muon detector in Run 3
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-09 · 1089 · 171588
DOI: 10.1016/j.nima.2026.171588 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-09. Verfasst von P. Albicocco und 39 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, National Science Foundation, Nuclear Physics.
Abstract (Originalsprache)
In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from $4\times 10^{32}\rm{cm}^{-2}\rm{s}^{-1}$ to $2\times 10^{33}\rm{cm}^{-2}\rm{s}^{-1}$. Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90\% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.
Förderung
- European Research Council
- National Science Foundation
- Nuclear Physics
- Istituto Nazionale di Fisica Nucleare
- National Natural Science Foundation of China
- Centre National de la Recherche Scientifique
- Ministry of Science and Technology of the People's Republic of China
- CERN
Zitieren
APA
Albicocco, P., Anelli, M., Archilli, F., Atzeni, M., Baldini, W., Balla, A., Belin, S., Bondar, N., Brundu, D., Cadeddu, S., Calì, S., Cardini, A., Carletti, M., Vidal, A. C., Chulikov, V., Chubykin, A., Ciambrone, P., Congedo, L., Contu, A., …, & Martellotti, G. (2026). Performance of the LHCb muon detector in Run 3. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1089, 171588. https://doi.org/10.1016/j.nima.2026.171588
Vancouver
Albicocco P, Anelli M, Archilli F, Atzeni M, Baldini W, Balla A, et al. Performance of the LHCb muon detector in Run 3. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1089:171588. doi:10.1016/j.nima.2026.171588
BibTeX
@article{Albicocco2026,
author = {Albicocco, P. and Anelli, M. and Archilli, F. and Atzeni, M. and Baldini, W. and Balla, A. and Belin, S. and Bondar, N. and Brundu, D. and Cadeddu, S. and Calì, S. and Cardini, A. and Carletti, M. and Vidal, A. Casais and Chulikov, V. and Chubykin, A. and Ciambrone, P. and Congedo, L. and Contu, A. and Debernardis, F. and Lucia, E. De and Robertis, G. De and Serio, M. De and Simone, P. De and Dettori, F. and Dreyfus, L. and Dzyuba, A. and Felici, G. and Gatta, M. and Granik, A. and Graziani, G. and Ilin, D. and Kotriakhova, S. and Kristic, R. and Lai, A. and Litvinov, R. and Manca, G. and Manganella, F. and Mariani, S. and Martellotti, G.},
title = {Performance of the LHCb muon detector in Run 3},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2026},
volume = {1089},
pages = {171588},
doi = {10.1016/j.nima.2026.171588}
}