EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Temperature dependence of the time resolution in a SiPM-readout plastic scintillator for cosmic-ray applications

José Reyes Castillo, Saúl Aguilar Salazar, Diego Mauricio Gomez Coral

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-08 · 1088 · 171550

DOI: 10.1016/j.nima.2026.171550 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-08. Verfasst von José Reyes Castillo und 2 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Nacional de Misiones, Universidad Nacional Autónoma de México, National Autonomous University of Mexico Directorate General of Academic Staff Affairs.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these systems can be affected by temperature variations encountered in flight. In this work, a time-of-flight (TOF) prototype consisting of a BC418 plastic scintillator bar coupled to Onsemi MICROFC-30050 SiPMs was constructed and tested under a controlled thermal environment between -20 and 20$^{\circ}$C. Electrons from a $^{90}\text{Sr}$ source were used as a beam, and a dedicated differential preamplifier and coincidence triggering were implemented to study the detector response. A minimum time resolution of 160ps was achieved at an overvoltage of 3V, remaining stable across the tested temperature range and uniform along the scintillator bar.

Förderung

  • Universidad Nacional de Misiones
  • Universidad Nacional Autónoma de México
  • National Autonomous University of Mexico Directorate General of Academic Staff Affairs
  • SECIHTI

Zitieren

APA

Castillo, J. R., Salazar, S. A., & Coral, D. M. G. (2026). Temperature dependence of the time resolution in a SiPM-readout plastic scintillator for cosmic-ray applications. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1088, 171550. https://doi.org/10.1016/j.nima.2026.171550

Vancouver

Castillo JR, Salazar SA, Coral DMG. Temperature dependence of the time resolution in a SiPM-readout plastic scintillator for cosmic-ray applications. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1088:171550. doi:10.1016/j.nima.2026.171550

BibTeX
@article{Castillo2026,
  author = {Castillo, José Reyes and Salazar, Saúl Aguilar and Coral, Diego Mauricio Gomez},
  title = {Temperature dependence of the time resolution in a SiPM-readout plastic scintillator for cosmic-ray applications},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2026},
  volume = {1088},
  pages = {171550},
  doi = {10.1016/j.nima.2026.171550}
}
Kostenlos starten →