Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-08 · 1088 · 171523
DOI: 10.1016/j.nima.2026.171523 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-08. Verfasst von A. Somov und 13 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Gefördert von: Nuclear Physics, Office of Science, U.S. Department of Energy.
Abstract (Originalsprache)
A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO$_4$) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection. The paper describes the design, installation, and performance of the light monitoring system.
Förderung
- Nuclear Physics
- Office of Science
- U.S. Department of Energy
- National Science Foundation
Zitieren
APA
Somov, A., Berdnikov, V., Voskanyan, H., Asaturyan, A., Gan, L., Taylor, S., Barbosa, F., Stanislav, C., Popov, V., Somov, I., Jaegle, I., Smith, A., Egiyan, H., & Bunton, B. (2026). Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1088, 171523. https://doi.org/10.1016/j.nima.2026.171523
Vancouver
Somov A, Berdnikov V, Voskanyan H, Asaturyan A, Gan L, Taylor S, et al. Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1088:171523. doi:10.1016/j.nima.2026.171523
BibTeX
@article{Somov2026,
author = {Somov, A. and Berdnikov, V.V. and Voskanyan, H. and Asaturyan, A. and Gan, L. and Taylor, S. and Barbosa, F. and Stanislav, C. and Popov, V. and Somov, I. and Jaegle, I. and Smith, A. and Egiyan, H. and Bunton, B.},
title = {Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2026},
volume = {1088},
pages = {171523},
doi = {10.1016/j.nima.2026.171523}
}
EUVIMED