High-resolution Multi-Reflection Time-of-Flight Mass Spectrometer for exotic nuclei at IGISOL

V.A. Virtanen, T. Eronen, A. Kankainen, O. Beliuskina, Z. Ge, R.P. de Groote, A. Jokinen, M. Mougeot, A. de Roubin, J. Ruotsalainen, J. Sarén, A. Takkinen

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-08 · 1088 · 171513

DOI: 10.1016/j.nima.2026.171513 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-08. Verfasst von V.A. Virtanen und 11 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: European Research Council, Horizon 2020 Framework Programme, Ellen ja Artturi Nyyssösen Säätiö.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A Multi-Reflection Time-of-Flight Mass Spectrometer (MR-ToF-MS) has been commissioned at the Ion-Guide Isotope Separator On-Line (IGISOL) facility. It consists of six electrode pairs that form a nearly energy-isochronous potential and a pulsed drift-tube to trap the ions between the electrodes. Time-of-flight peak widths down to 22 ns full-width at half-maximum and mass-resolving powers of $\approx 1.5 \times 10^5$ within 20 ms have been demonstrated. The obtained time-focus and mass-resolving power depend sensitively on the trapping energy, energy spread and the number of revolutions of the ions. The mass-resolving power is affected by the temporal and energy spread of the ions entering the MR-ToF-MS, and fluctuations in the electrode voltages due to temperature variations. The longitudinal emittance corresponding to the temporal and energy spread of $^{39}$K is estimated to be 175 eVns based on the data, close to the expected 186(10) eVns. The time-of-flight temperature sensitivity is found to be -5.55(30) ppm/K. In addition to atomic mass measurements of short-lived exotic nuclides, the MR-ToF-MS can be used as a fast mass separator for various other experiments at IGISOL and as an ion counter for laser spectroscopy and yield measurements.

Förderung

  • European Research Council
  • Horizon 2020 Framework Programme
  • Ellen ja Artturi Nyyssösen Säätiö
  • Vilho Yrjö and Kalle Väisälä Fund
  • Research Council of Finland
  • Universität Greifswald

Zitieren

APA

Virtanen, V., Eronen, T., Kankainen, A., Beliuskina, O., Ge, Z., Groote, R. D., Jokinen, A., Mougeot, M., Roubin, A. D., Ruotsalainen, J., Sarén, J., & Takkinen, A. (2026). High-resolution Multi-Reflection Time-of-Flight Mass Spectrometer for exotic nuclei at IGISOL. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1088, 171513. https://doi.org/10.1016/j.nima.2026.171513

Vancouver

Virtanen V, Eronen T, Kankainen A, Beliuskina O, Ge Z, Groote RD, et al. High-resolution Multi-Reflection Time-of-Flight Mass Spectrometer for exotic nuclei at IGISOL. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1088:171513. doi:10.1016/j.nima.2026.171513

BibTeX
@article{Virtanen2026,
  author = {Virtanen, V.A. and Eronen, T. and Kankainen, A. and Beliuskina, O. and Ge, Z. and Groote, R.P. de and Jokinen, A. and Mougeot, M. and Roubin, A. de and Ruotsalainen, J. and Sarén, J. and Takkinen, A.},
  title = {High-resolution Multi-Reflection Time-of-Flight Mass Spectrometer for exotic nuclei at IGISOL},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2026},
  volume = {1088},
  pages = {171513},
  doi = {10.1016/j.nima.2026.171513}
}
Kostenlos starten →