Data sorting modes of phoswich detector array
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-06 · 1086 · 171337
DOI: 10.1016/j.nima.2026.171337 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-06. Verfasst von R. Li und 33 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: China Scholarship Council, H2020 European Research Council, Horizon 2020 Framework Programme.
Abstract (Originalsprache)
The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4$-$10 MeV) $\gamma$ rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the $\beta$-decay experiment of $^{80g+m}$Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2"$\times$2"$\times$2"LaBr$_3$(Ce) detector (Ciema{\l}a et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr$_3$(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.
Förderung
- China Scholarship Council
- H2020 European Research Council
- Horizon 2020 Framework Programme
- European Research Council
Zitieren
APA
Li, R., Verney, D., Delafosse, C., Harakeh, M., Maj, A., Didierjean, F., Ayoubi, L. A., Falou, H. A., Bednarczyk, P., Benzoni, G., Blanc, F. L., Bozkurt, V., Ciemała, M., Crespi, F., Deloncle, I., Gaulard, C., Gottardo, A., Guadilla, V., Guillot, J., …, & Tocabens, G. (2026). Data sorting modes of phoswich detector array. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1086, 171337. https://doi.org/10.1016/j.nima.2026.171337
Vancouver
Li R, Verney D, Delafosse C, Harakeh M, Maj A, Didierjean F, et al. Data sorting modes of phoswich detector array. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1086:171337. doi:10.1016/j.nima.2026.171337
BibTeX
@article{Li2026,
author = {Li, R. and Verney, D. and Delafosse, C. and Harakeh, M.N. and Maj, A. and Didierjean, F. and Ayoubi, L. Al and Falou, H. Al and Bednarczyk, P. and Benzoni, G. and Blanc, F. Le and Bozkurt, V. and Ciemała, M. and Crespi, F.C.L. and Deloncle, I. and Gaulard, C. and Gottardo, A. and Guadilla, V. and Guillot, J. and Hadyńska-Klęk, K. and Ibrahim, F. and Jovancevic, N. and Kankainen, A. and Kmiecik, M. and Lebois, M. and Martínez, T. and Napiorkowski, P. and Roussiere, B. and Sobolev, Yu. G. and Stanoiu, M. and Stefan, I. and Stukalov, S. and Thisse, D. and Tocabens, G.},
title = {Data sorting modes of phoswich detector array},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2026},
volume = {1086},
pages = {171337},
doi = {10.1016/j.nima.2026.171337}
}
EUVIMED