The CMS barrel timing layer: test beam confirmation of module timing performance
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2026-01 · 1081 · 170823
DOI: 10.1016/j.nima.2025.170823 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2026-01. Verfasst von F. Addesa und 39 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Ministry of Science and Technology of the People's Republic of China, Latvijas Zinātnes Padome.
Abstract (Originalsprache)
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm \mu m$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.
Förderung
- European Commission
- Ministry of Science and Technology of the People's Republic of China
- Latvijas Zinātnes Padome
- National Key Research and Development Program of China
- International Council of Shopping Centers
- FCT
- National Natural Science Foundation of China
Zitieren
APA
Addesa, F., Akrap, P., Albert, A., Allmond, B., Anderson, T., Babbar, J., Baranyai, D., Barria, P., Basile, C., Benaglia, A., Benato, A., Benettoni, M., Besancon, M., Bez, N., Bhattacharya, S., Bianco, R., Blend, D., Boletti, A., Bornheim, A., …, & Fernandez, E. (2026). The CMS barrel timing layer: test beam confirmation of module timing performance. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1081, 170823. https://doi.org/10.1016/j.nima.2025.170823
Vancouver
Addesa F, Akrap P, Albert A, Allmond B, Anderson T, Babbar J, et al. The CMS barrel timing layer: test beam confirmation of module timing performance. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2026;1081:170823. doi:10.1016/j.nima.2025.170823
BibTeX
@article{Addesa2026,
author = {Addesa, F. and Akrap, P. and Albert, A. and Allmond, B. and Anderson, T. and Babbar, J. and Baranyai, D. and Barria, P. and Basile, C. and Benaglia, A. and Benato, A. and Benettoni, M. and Besancon, M. and Bez, N. and Bhattacharya, S. and Bianco, R. and Blend, D. and Boletti, A. and Bornheim, A. and Bugalho, R. and Bulla, A. and Cardwell, B. and Carlin, R. and Casarsa, M. and Cetorelli, F. and Cossutti, F. and Cox, B. and Molin, G. Da and Guio, F. De and Leo, K. De and Riggi, F. De and Debbins, P. and Re, D. Del and Gatti, R. Delli and Dervan, J. and Devouge, P. and Dreimanis, K. and Eberlins, O.M. and Errico, F. and Fernandez, E.},
title = {The CMS barrel timing layer: test beam confirmation of module timing performance},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2026},
volume = {1081},
pages = {170823},
doi = {10.1016/j.nima.2025.170823}
}
EUVIMED