Development and validation of a high-fidelity full-spectrum Monte Carlo model for the Swiss airborne gamma-ray spectrometry system

David Breitenmoser, Alberto Stabilini, Malgorzata Magdalena Kasprzak, Sabine Mayer

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2025-08 · 1077 · 170512

DOI: 10.1016/j.nima.2025.170512 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2025-08. Verfasst von David Breitenmoser und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Airborne Gamma-Ray Spectrometry (AGRS) is a critical tool for radiological emergency response, enabling the rapid identification and quantification of hazardous terrestrial radionuclides over large areas. However, existing calibration methods are limited to a few gamma-ray sources, excluding most radionuclides released in severe nuclear accidents and nuclear weapon detonations, compromising effective response and risk assessment. Here, we present a high-fidelity Monte Carlo model that overcomes these limitations, offering full-spectrum calibration for any gamma-ray source. Unlike previous approaches, our model integrates a detailed mass model of the aircraft and a calibrated non-proportional scintillation model, enabling accurate event-by-event predictions of the spectrometer's response to arbitrarily complex gamma-ray fields. Validation in near-, mid-, and far-field scenarios demonstrates that the model not only addresses major deficiencies of previous approaches but also achieves the accuracy required to supersede empirical calibration methods. This advancement enables high-fidelity spectral signature generation for any gamma-ray source, reduces calibration time and costs, minimizes reliance on high-intensity sources, and eliminates related radioactive waste. The approach presented here is a critical step toward integrating advanced full-spectrum data reduction methods for AGRS, unlocking new capabilities beyond emergency response, such as atmospheric cosmic-ray flux quantification for geophysics and trace-level airborne radionuclide identification for nuclear security.

Zitieren

APA

Breitenmoser, D., Stabilini, A., Kasprzak, M. M., & Mayer, S. (2025). Development and validation of a high-fidelity full-spectrum Monte Carlo model for the Swiss airborne gamma-ray spectrometry system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1077, 170512. https://doi.org/10.1016/j.nima.2025.170512

Vancouver

Breitenmoser D, Stabilini A, Kasprzak MM, Mayer S. Development and validation of a high-fidelity full-spectrum Monte Carlo model for the Swiss airborne gamma-ray spectrometry system. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2025;1077:170512. doi:10.1016/j.nima.2025.170512

BibTeX
@article{Breitenmoser2025,
  author = {Breitenmoser, David and Stabilini, Alberto and Kasprzak, Malgorzata Magdalena and Mayer, Sabine},
  title = {Development and validation of a high-fidelity full-spectrum Monte Carlo model for the Swiss airborne gamma-ray spectrometry system},
  journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
  year = {2025},
  volume = {1077},
  pages = {170512},
  doi = {10.1016/j.nima.2025.170512}
}
Kostenlos starten →