ALCOR: A mixed-signal ASIC for the dRICH detector of the ePIC experiment at the EIC
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2024-12 · 1069 · 169817
DOI: 10.1016/j.nima.2024.169817 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024-12. Verfasst von F. Cossio und 36 weiteren Autor:innen. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020, Nuclear Physics Office.
Abstract (Originalsprache)
We present a mixed-signal ASIC, called ALCOR (A Low-power Chip for Optical sensor Readout), designed for the readout and digitization of signals from Silicon Photomultipliers (SiPMs) in the framework of the dual-radiator RICH (dRICH) detector of the electron–Proton/Ion Collider (ePIC) experiment at the Electron–Ion Collider (EIC). ALCOR features 32 channels arranged in an 8x4 matrix. The amplifier input stage is a low impedance current conveyor based on a regulated common-gate topology. The versatile front-end is able to work with positive or negative input polarity signals and includes four gain settings and two discriminators with 6-bit DAC programmable thresholds. Each channel also incorporates quad-buffered low-power TDCs based on analogue interpolation providing precise timestamping with a 25–50 ps time bin. ALCOR is designed in a 110 nm CMOS technology and the power consumption is about 10–12 mW per channel. The ASIC has been extensively tested in the laboratory standalone and coupled to different SiPM models to assess its functionality and performance. The results have been validated in a beam test campaign with a prototype of the dRICH detector and 1280 3 × 3 mm 2 SiPM sensors.
Förderung
- H2020
- Nuclear Physics Office
Zitieren
APA
Cossio, F., Achari, B., Agrawal, N., Alexeev, M., Alice, C., Antonioli, P., Baldanza, C., Barion, L., Bortone, A., Calivà, A., Capua, M., Chiosso, M., Contalbrigo, M., Rolo, M. D. R., Caro, A. D., Gruttola, D. D., Dellacasa, G., Falchieri, D., Fazio, S., …, & Wheadon, R. (2024). ALCOR: A mixed-signal ASIC for the dRICH detector of the ePIC experiment at the EIC. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1069, 169817. https://doi.org/10.1016/j.nima.2024.169817
Vancouver
Cossio F, Achari B, Agrawal N, Alexeev M, Alice C, Antonioli P, et al. ALCOR: A mixed-signal ASIC for the dRICH detector of the ePIC experiment at the EIC. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2024;1069:169817. doi:10.1016/j.nima.2024.169817
BibTeX
@article{Cossio2024,
author = {Cossio, F. and Achari, B.R. and Agrawal, N. and Alexeev, M. and Alice, C. and Antonioli, P. and Baldanza, C. and Barion, L. and Bortone, A. and Calivà, A. and Capua, M. and Chiosso, M. and Contalbrigo, M. and Rolo, M. Da Rocha and Caro, A. De and Gruttola, D. De and Dellacasa, G. and Falchieri, D. and Fazio, S. and Funicello, N. and Garbini, M. and Giacalone, M. and Giordano, D. and Mignone, M. and Malaguti, R. and Preghenella, R. and Panzieri, D. and Paladino, A. and Occhiuto, L. and Rignanese, L.P. and Ripoli, C. and Rubini, N. and Ruspa, M. and Tassi, E. and Tuvé, C. and Vallarino, S. and Wheadon, R.},
title = {ALCOR: A mixed-signal ASIC for the dRICH detector of the ePIC experiment at the EIC},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2024},
volume = {1069},
pages = {169817},
doi = {10.1016/j.nima.2024.169817}
}
EUVIMED