Investigating the image lag of a scientific CMOS sensor in X-ray detection
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · 2023-05 · 1050 · 168180
DOI: 10.1016/j.nima.2023.168180 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023-05. Verfasst von Qinyu Wu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chinese Academy of Sciences.
Abstract (Originalsprache)
In recent years, scientific CMOS (sCMOS) sensors have been vigorously developed and have outperformed CCDs in several aspects: higher readout frame rate, higher radiation tolerance, and higher working temperature. For silicon image sensors, image lag will occur when the charges of an event are not fully transferred inside pixels. It can degrade the image quality for optical imaging, and deteriorate the energy resolution for X-ray spectroscopy. In this work, the image lag of a sCMOS sensor is studied. To measure the image lag under low-light illumination, we constructed a new method to extract the image lag from X-ray photons. The image lag of a customized X-ray sCMOS sensor GSENSE1516BSI is measured, and its influence on X-ray performance is evaluated. The result shows that the image lag of this sensor exists only in the immediately subsequent frame and is always less than 0.05% for different incident photon energies and under different experimental conditions. The residual charge is smaller than 0.5 e- with the highest incident photon charge around 8 ke-. Compared to the readout noise level around 3 e-, the image lag of this sensor is too small to have a significant impact on the imaging quality and the energy resolution. The image lag shows a positive correlation with the incident photon energy and a negative correlation with the temperature. However, it has no dependence on the gain setting and the integration time. These relations can be explained qualitatively by the non-ideal potential structure inside the pixels. This method can also be applied to the study of image lag for other kinds of imaging sensors.
Förderung
- National Natural Science Foundation of China
- Chinese Academy of Sciences
Zitieren
APA
Wu, Q., Ling, Z., Zhang, C., Zhou, Q., Wang, X., Yuan, W., & Zhang, S. (2023). Investigating the image lag of a scientific CMOS sensor in X-ray detection. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1050, 168180. https://doi.org/10.1016/j.nima.2023.168180
Vancouver
Wu Q, Ling Z, Zhang C, Zhou Q, Wang X, Yuan W, et al. Investigating the image lag of a scientific CMOS sensor in X-ray detection. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2023;1050:168180. doi:10.1016/j.nima.2023.168180
BibTeX
@article{Wu2023,
author = {Wu, Qinyu and Ling, Zhixing and Zhang, Chen and Zhou, Quan and Wang, Xinyang and Yuan, Weimin and Zhang, Shuang-Nan},
title = {Investigating the image lag of a scientific CMOS sensor in X-ray detection},
journal = {Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment},
year = {2023},
volume = {1050},
pages = {168180},
doi = {10.1016/j.nima.2023.168180}
}
EUVIMED