Intersession reliability of transcranial magnetic stimulation measures of interhemispheric inhibition
Neuroscience · 2026
DOI: 10.1016/j.neuroscience.2026.08.034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neuroscience, 2026. Verfasst von F C Adams und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology, McMaster University, Canada. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Functional Laterality, Neural Inhibition, Motor Cortex. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Interhemispheric inhibition (IHI) reflects transcallosal interactions between bilateral primary motor cortices and is commonly assessed using a paired-pulse, transcranial magnetic stimulation (TMS) paradigm, in which a conditioning TMS pulse is delivered to M1 prior to a test TMS pulse delivered to the contralateral M1. Despite its widespread use as a marker of interhemispheric connectivity and intervention-related plasticity, its reliability remains unclear. The present study assessed the intersession reliability of short- (SIHI: 8, 10 ms) and long-latency IHI (LIHI: 40, 50 ms) recorded from the right and left first dorsal interosseous muscles in right-hand dominant healthy controls. Relative reliability was quantified using intraclass correlation coefficients (ICC), and absolute reliability was quantified using the standard error of measurement (SEM) and smallest detectable change (SDC). SIHI and LIHI demonstrated moderate-to-strong reliability when measured from the right, dominant hand with the greatest reliability observed at 8 ms (SIHI) and 50 ms (LIHI). Reliability of IHI was consistently lower in the left hand. Across conditions, measurement error was high, resulting in large SDC values at the individual level, indicating limited sensitivity for detecting individual change. In contrast, group-level SDC estimates were substantially lower, supporting the use of IHI for detecting group level effects with appropriate sample sizes (∼23 for SIHI; ∼18 for LIHI in the dominant hand of right-handed individuals). These findings indicate that while IHI can provide reliable group-level measures of interhemispheric function, its application for tracking individual changes across sessions may be limited.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Kinesiology, McMaster University, Canada.
- Department of Kinesiology, McMaster University, Canada; School of Biomedical Engineering, McMaster University, Canada. Electronic address: nelsonaj@mcmaster.ca.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Adams, F. C., Hussain, M., Ramdeo, K. R., Ahmad, M., & Nelson, A. J. (2026). Intersession reliability of transcranial magnetic stimulation measures of interhemispheric inhibition. Neuroscience. https://doi.org/10.1016/j.neuroscience.2026.08.034
Vancouver
Adams FC, Hussain M, Ramdeo KR, Ahmad M, Nelson AJ. Intersession reliability of transcranial magnetic stimulation measures of interhemispheric inhibition. Neuroscience. 2026. doi:10.1016/j.neuroscience.2026.08.034
BibTeX
@article{Adams2026,
author = {Adams, F C and Hussain, M and Ramdeo, K R and Ahmad, M and Nelson, A J},
title = {Intersession reliability of transcranial magnetic stimulation measures of interhemispheric inhibition},
journal = {Neuroscience},
year = {2026},
doi = {10.1016/j.neuroscience.2026.08.034}
}
EUVIMED