Machine-based classification of epileptiform activity in selected EEG excerpts from genetic generalised epilepsy
Neurophysiologie Clinique · 2026
DOI: 10.1016/j.neucli.2026.103191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurophysiologie Clinique, 2026. Verfasst von Juan Manuel Escobar-Montalvo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Henares University Hospital, Neurology and Clinical Neurophysiology Department, Madrid, Spain; Medical Analysis Expert Group, Castilla-La Mancha Inst…. Hauptthemen laut MEDLINE: Epilepsy, Generalized, Electroencephalography, Deep Learning. Die Arbeit nennt 56 Literaturangaben. Gefördert von: Universidad de Castilla-La Mancha.
Abstract (Originalsprache)
OBJECTIVES: To evaluate whether the deep learning model IGENet-TS, a time-domain convolutional neural network (CNN), can classify expert-selected EEG excerpts containing visible generalised epileptiform activity from genetic generalised epilepsy (GGE) versus normal healthy-control excerpts, and whether this selected-excerpt task generalises across centres. METHODS: We performed a retrospective selected-excerpt classification study of 455 routine 32-channel EEGs: 237 from Cuenca (107 GGE, 130 controls) for development and 218 from Bremen (106 GGE, 112 controls) for external testing. Each GGE recording contributed a 120-s resting-state segment containing at least one visible generalised discharge; controls contributed representative normal resting background. IGENet-TS analysed thirty non-overlapping 4-s windows per segment and averaged window probabilities to obtain a segment-derived label. RESULTS: Repeated 70:30 internal testing yielded sensitivity 98.15% (95% CI 97.52-98.78), specificity against healthy-control excerpts 97.95% (97.40-98.50), accuracy 98.04% (97.45-98.63), F1 98.05% (97.50-98.60) and AUC 0.98 (0.96-1.00). Externally, sensitivity was 97.02% (96.39-97.65), specificity against healthy-control excerpts 96.80% (96.19-97.41), accuracy 96.91% (96.24-97.58), F1 96.62% (95.97-97.27) and AUC 0.97 (0.95-0.99). DISCUSSION/CONCLUSION: The IGENet-TS model distinguished curated discharge-containing GGE excerpts from normal healthy-control excerpts with stable centre-separated performance. These results support technical feasibility for the selected-excerpt classification task, but do not validate unattended full-recording EEG interpretation or clinical workflow use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Henares University Hospital, Neurology and Clinical Neurophysiology Department, Madrid, Spain; Medical Analysis Expert Group, Castilla-La Mancha Institute of Health Research (IDISCAM), Toledo, 45071, Spain.
- Medical Analysis Expert Group, Castilla-La Mancha Institute of Health Research (IDISCAM), Toledo, 45071, Spain; Medical Analysis Expert Group, Institute of Technology, University of Castilla-La Mancha, Cuenca, 16071, Sp…
Förderung
- Universidad de Castilla-La Mancha
Zitieren
APA
Escobar-Montalvo, J. M., Torres, A. M., Escobar-Ipuz, F., & Mateo, J. (2026). Machine-based classification of epileptiform activity in selected EEG excerpts from genetic generalised epilepsy. Neurophysiologie Clinique. https://doi.org/10.1016/j.neucli.2026.103191
Vancouver
Escobar-Montalvo JM, Torres AM, Escobar-Ipuz F, Mateo J. Machine-based classification of epileptiform activity in selected EEG excerpts from genetic generalised epilepsy. Neurophysiologie Clinique. 2026. doi:10.1016/j.neucli.2026.103191