Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique
Neurochirurgie · 2024
DOI: 10.1016/j.neuchi.2024.101560 ↗Kurz gefasst
Fallbericht in der Zeitschrift Neurochirurgie, 2024. Verfasst von Thomas Chevillotte und 5 weiteren Autor:innen. Beteiligte Einrichtung: Spine Institute, Clinique Charcot, 51 rue Commandant Charcot, 69110, Sainte-Foy-lès-Lyon, France. Electronic address: dr.chevillotte@gmail.com. Hauptthemen laut MEDLINE: Spinal Fusion, Lumbar Vertebrae, Spondylolisthesis, Sacrum. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: In case of high sacral slope, anterior lumbosacral fusions can be performed by retroperitoneal or transperitoneal approach using a reversed Bohlman technique with an autologous corticocancellous fibular graft. The use of a trans-lumbosacral implant can avoid the iatrogenic effects but currently, there is no implant specifically designed for this fusion technique. Could the IFUSE implant from SI BONE replace a fibular graft to avoiding the iatrogenic effect induced by sampling during a Reverse Bohlman technique? PATIENTS AND METHODS: We present the case of a 38-year-old woman with L5S1 interbody pseudarthrosis after posterior fixation for grade 2 L5-S1 spondylolisthesis with isthmic lysis of L5, and that of a 69-year-old woman who underwent a posterior T4 fusion to the pelvis for degenerative scoliosis. Both required a trans-lumbosacral instrumented fusion via an anterior approach using the reverse Bohlman technique. Surgical technique was described. RESULTS: There were no perioperative or postoperative complications. At 6 months, the patients reported a decrease in lumbar and radicular symptomatology. There were no infectious, neurological or vascular complications. CT-scans confirmed the good position and stability of the IFUSE implant. DISCUSSION: We present an innovative interbody grafting technique adapted to spines with high pelvic incidence. The surgical technique is safe, minimally invasive, and reduces surgical iatrogeny. The short and medium-term results are positive but require longer-term follow-up and a larger cohort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Spine Institute, Clinique Charcot, 51 rue Commandant Charcot, 69110, Sainte-Foy-lès-Lyon, France. Electronic address: dr.chevillotte@gmail.com.
- Spine Institute, Clinique Charcot, 51 rue Commandant Charcot, 69110, Sainte-Foy-lès-Lyon, France.
Zitieren
APA
Chevillotte, T., Darnis, A., Grobost, P., Palmano, M., Guedj, J., & Silvestre, C. (2024). Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique. Neurochirurgie. https://doi.org/10.1016/j.neuchi.2024.101560
Vancouver
Chevillotte T, Darnis A, Grobost P, Palmano M, Guedj J, Silvestre C. Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique. Neurochirurgie. 2024. doi:10.1016/j.neuchi.2024.101560
BibTeX
@article{Chevillotte2024,
author = {Chevillotte, Thomas and Darnis, Alice and Grobost, Pierre and Palmano, Marine and Guedj, Jérémie and Silvestre, Clément},
title = {Instrumented L5-S1 interbody graft with IFUSE implant using the reverse Bohlman technique},
journal = {Neurochirurgie},
year = {2024},
doi = {10.1016/j.neuchi.2024.101560}
}