EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Discordance between extracellular volume and hemodynamic congestion in hemodialysis: A pilot multiparametric study

Jonas El Bachouti, César Ruiz García, María Alba Herreros, Elisabet Coll

Nefrología · 2026-11 · 46 (9) · 501590

DOI: 10.1016/j.nefro.2026.501590 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nefrología, 2026-11. Verfasst von Jonas El Bachouti und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Fluid status assessment in patients undergoing hemodialysis (HD) remains a major clinical challenge, as no single reference method is currently available. Different tools, such as bioelectrical impedance spectroscopy (BIS), point-of-care ultrasound (PoCUS), and clinical assessment, explore distinct pathophysiological domains. The aim of this study was to evaluate the complementary role of different bedside tools assessing volume overload and hemodynamic congestion in HD patients. Materials and Methods: This was a cross-sectional pilot study including 15 prevalent HD patients. A multiparametric pre-dialysis assessment was performed using BIS, PoCUS (lung ultrasound B-lines, inferior vena cava, and portal vein Doppler), and clinical evaluation. Congestion biomarkers, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and carbohydrate antigen 125 (CA-125), were also analyzed. Exploratory descriptive agreement analyses using the weighted kappa coefficient, together with correlation analyses, were performed.

Results

BIS identified volume overload in 80% of patients, compared to 26.7% by clinical assessment and 13.3% by PoCUS. Exploratory agreement analyses showed moderate concordance between clinical assessment and PoCUS (κ = 0.59), low concordance between clinical assessment and BIS (κ = 0.19), and very low concordance between BIS and PoCUS (κ = 0.06). PoCUS identified a subgroup of patients with ultrasound findings suggestive of hemodynamic congestion, all corresponding to mild congestion. NT-proBNP levels were associated with both clinical congestion and BIS-estimated volume overload (rho ≈ 0.67; p = 0.007), while CA-125 showed a positive correlation with volume overload (rho ≈ 0.58; p = 0.025).

Conclusions

Different bedside tools identified divergent but complementary patterns of extracellular volume overload and hemodynamic congestion in HD patients. BIS, PoCUS, and clinical assessment should not be interpreted as equivalent or interchangeable tools, but rather as complementary methods exploring distinct physiological and hemodynamic domains. These exploratory findings support a multiparametric approach to fluid status evaluation and require confirmation in larger studies.

Zitieren

APA

Bachouti, J. E., García, C. R., Herreros, M. A., & Coll, E. (2026). Discordance between extracellular volume and hemodynamic congestion in hemodialysis: A pilot multiparametric study. Nefrología, 46(9), 501590. https://doi.org/10.1016/j.nefro.2026.501590

Vancouver

Bachouti JE, García CR, Herreros MA, Coll E. Discordance between extracellular volume and hemodynamic congestion in hemodialysis: A pilot multiparametric study. Nefrología. 2026;46(9):501590. doi:10.1016/j.nefro.2026.501590

BibTeX
@article{Bachouti2026,
  author = {Bachouti, Jonas El and García, César Ruiz and Herreros, María Alba and Coll, Elisabet},
  title = {Discordance between extracellular volume and hemodynamic congestion in hemodialysis: A pilot multiparametric study},
  journal = {Nefrología},
  year = {2026},
  volume = {46},
  number = {9},
  pages = {501590},
  doi = {10.1016/j.nefro.2026.501590}
}
Kostenlos starten →