EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pre-analytical properties of different respiratory viruses for PCR-based detection: Comparative analysis of sampling devices and sample stabilization solutions

Melina Hardt, Franziska Kaiser, Thorsten Voss, Uwe Oelmüller, Kurt Zatloukal

New Biotechnology · 2024-03 · 79 · 60-70

DOI: 10.1016/j.nbt.2023.12.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift New Biotechnology, 2024-03. Verfasst von Melina Hardt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic, and Research Center for Molecular Biomedicine, Diagnostic, and Research Institute of Pathology, Medical University of Graz, Graz, Austria. Hauptthemen laut MEDLINE: Influenza, Human, Viruses. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

After the decline of the COVID-19 pandemic, health systems were challenged by the simultaneous prevalence of different respiratory viruses causing a wide overlap in symptoms. This increased the demand for multi-virus diagnostic tests which require suitable pre-analytical workflow solutions in order to receive valid diagnostic results. In this context, the effects of specimen storage duration and temperature on the RNA/DNA copy number stability of influenza A/B, RSV A/B, SARS-CoV-2 and adenovirus were examined for four commercially available transport swab systems and saliva collection devices. The respiratory viruses were more stable in the saliva collection devices than in the transport swab systems when stored at RT or 37 °C for up to 96 h. Moreover, no differences between viral nucleic acid stability of enveloped and non-enveloped viruses were observed. The infectivity of all enveloped viruses could be inactivated by the saliva collection device from PreAnalytiX. The Norgen saliva device completely inactivated influenza A/B, while RSV A/B were partially inactivated. The non-enveloped adenovirus was inactivated by a reduction factor of 10E+ 4 in both saliva collection devices. All respiratory viruses remained infectious in the transport swab systems. Two possible transport medium additives were tested which inactivated or strongly reduced viral replication of tested enveloped viruses but had no effect on the non-enveloped adenovirus. Finally the implementation of multi-target detection procedures involving a direct amplification approach was successfully tested by spike-in of all enveloped viruses simultaneously into transport swab systems. This fast and reproducible setup presents a valuable solution for future implementations in multi-virus testing strategies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Influenza, HumanVirusesHumansPandemicsSpecimen HandlingPolymerase Chain Reaction

Stichwörter der Autor:innen

AdenovirusDNA stabilityInfectivityInfluenzaMulti-targetPre-analyticalPre-analyticsRNA stabilityRSVSARS-CoV-2Saliva collection devicesTransport swab systems

Autor:innen und Institutionen

  • Diagnostic, and Research Center for Molecular Biomedicine, Diagnostic, and Research Institute of Pathology, Medical University of Graz, Graz, Austria.
  • QIAGEN GmbH, Hilden, Germany.
  • Diagnostic, and Research Center for Molecular Biomedicine, Diagnostic, and Research Institute of Pathology, Medical University of Graz, Graz, Austria. Electronic address: kurt.zatloukal@medunigraz.at.

Förderung

  • European Commission
  • Horizon 2020 Framework Programme

Zitieren

APA

Hardt, M., Kaiser, F., Voss, T., Oelmüller, U., & Zatloukal, K. (2024). Pre-analytical properties of different respiratory viruses for PCR-based detection: Comparative analysis of sampling devices and sample stabilization solutions. New Biotechnology, 79, 60-70. https://doi.org/10.1016/j.nbt.2023.12.005

Vancouver

Hardt M, Kaiser F, Voss T, Oelmüller U, Zatloukal K. Pre-analytical properties of different respiratory viruses for PCR-based detection: Comparative analysis of sampling devices and sample stabilization solutions. New Biotechnology. 2024;79:60-70. doi:10.1016/j.nbt.2023.12.005

BibTeX
@article{Hardt2024,
  author = {Hardt, Melina and Kaiser, Franziska and Voss, Thorsten and Oelmüller, Uwe and Zatloukal, Kurt},
  title = {Pre-analytical properties of different respiratory viruses for PCR-based detection: Comparative analysis of sampling devices and sample stabilization solutions},
  journal = {New Biotechnology},
  year = {2024},
  volume = {79},
  pages = {60--70},
  doi = {10.1016/j.nbt.2023.12.005}
}
Kostenlos starten →