Double-layer dehydrated amniotic membrane for ocular surface reconstruction: Biological and biomechanical effects of processing and storage methods
Materials Today Communications · 2026-12 · 57 · 116234
DOI: 10.1016/j.mtcomm.2026.116234 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials Today Communications, 2026-12. Verfasst von Kookyoung Kim und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study examined how sodium hypochlorite (SH), cryopreservation, and double-layer dehydration influence the structure, mechanical properties, and growth factor retention of human amniotic membrane (hAM) used for ocular surface reconstruction. hAM from a single donor was treated with normal saline (NS) or SH (0.025% or 0.25%) and assessed histologically and by tensile testing. Single-layer dehydrated (1LD) and double-layer dehydrated (2LD) hAM were compared with single-layer cryopreserved hAM without (1LC) or with (1LCS) low-dose SH pretreatment by quantifying 11 cytokines and growth factors with a multiplex bead-based immunoassay (n = 4 specimens per group). In single-specimen descriptive analyses, SH increased total membrane thickness and maximum point stress but caused epithelial thinning at 0.025% and epithelial loss at 0.25%. Double-layer dehydrated hAM retained the architecture of both layers after dehydration and was approximately 2.4-fold thicker than single-layer dehydrated hAM (67.5 vs. 27.7 µm). It also showed the highest total cytokine/growth factor and epidermal growth factor (EGF) levels, whereas cryopreserved and SH-pretreated cryopreserved hAM showed substantially lower levels. Double-layer dehydrated hAM therefore offers a mechanically robust, biologically active, and logistically convenient graft option for treating ocular surface disorders.
Zitieren
APA
Kim, K., Lee, M., Lee, S., So, J. W., & Lee, Y. (2026). Double-layer dehydrated amniotic membrane for ocular surface reconstruction: Biological and biomechanical effects of processing and storage methods. Materials Today Communications, 57, 116234. https://doi.org/10.1016/j.mtcomm.2026.116234
Vancouver
Kim K, Lee M, Lee S, So JW, Lee Y. Double-layer dehydrated amniotic membrane for ocular surface reconstruction: Biological and biomechanical effects of processing and storage methods. Materials Today Communications. 2026;57:116234. doi:10.1016/j.mtcomm.2026.116234
BibTeX
@article{Kim2026,
author = {Kim, Kookyoung and Lee, Myeong-Kyu and Lee, Sae-Rom and So, Jeong Won and Lee, Yongwoo},
title = {Double-layer dehydrated amniotic membrane for ocular surface reconstruction: Biological and biomechanical effects of processing and storage methods},
journal = {Materials Today Communications},
year = {2026},
volume = {57},
pages = {116234},
doi = {10.1016/j.mtcomm.2026.116234}
}
EUVIMED