EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Ultra-High-Field (7T) knee MRI: review of technical considerations and current evidence, with experience from an institutional clinical series

Sana Boudabbous, David Ferreira Branco, Philippe M Tscholl, Bénédicte Marie Anne Delattre, Laura Rubbia-Brandt, Hicham Bouredoucen, Pierre Alexandre Poletti, Didier Hannouche, Karl-Olof Lövblad, Felix T Kurz

Magnetic Resonance Imaging · 2026-11 · 110846

DOI: 10.1016/j.mri.2026.110846 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Magnetic Resonance Imaging, 2026-11. Verfasst von Sana Boudabbous und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland; Geneva University, Geneva, Switzerland; Image Guided …. Die Arbeit nennt 73 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ultra-high-field, 7 Tesla (T) MRI provides higher signal-to-noise ratio (SNR) and enables high-resolution 3D and quantitative imaging. Its role in musculoskeletal (MSK) knee imaging is emerging but not yet standardized.

Purpose

To review current 7 T knee MRI techniques and evidence, detail key technical/physics considerations, and to report a single-center clinical experience through a descriptive study.

Methods

Up to date narrative synthesis of the literature organized by qualitative (morphologic) and quantitative applications, complemented by experience from a retrospective single-center series of consecutive 7 T knee examinations.

Results

Literature shows that 7 T imaging can improve conspicuity of cartilage, meniscus, ligaments, and bone microarchitecture with isotropic 3D acquisitions; quantitative methods (T2/T2*, Ultrashort Echo Time (UTE), Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST), 23 Na, T1rho) show promise but require rigorous B0/B1 correction and Specific Absorption Rate (SAR) management. Our experience demonstrated that 7 T imaging was clinically feasible and well tolerated in a cohort of 131 patients (mean age 33.8 ± 10.5 years ranging from 16 to 63 years) and provided a potential and a subjective increase in diagnosis confidence in selected scenarios, particularly in postoperative meniscus assessment and conservative ACL follow-up.

Conclusion

7 T knee MRI is feasible and potentially impactful in specific indications; however, stronger comparative data, protocol harmonization, and quantitative validation are needed.

Schlagwörter

Stichwörter der Autor:innen

7 T MRIAnterior cruciate ligament (ACL)CartilageKneeQuantitative mappingReviewSodium MRIT1rhoUTEgagCESTmeniscus

Autor:innen und Institutionen

  • Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland; Geneva University, Geneva, Switzerland; Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of…
  • Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland. Electronic address: david.branco@hug.ch.
  • Division of Orthopedy, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland; Réseau Francophone Olympique de la Recherche en Médecine du Sport (ReFORM), IOC Research Centre for Injury Prevention and P…
  • Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland. Electronic address: Benedicte.Delattre@hug.ch.
  • Division of Pathology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland; Geneva University, Geneva, Switzerland. Electronic address: laura.rubbia-brandt@hug.ch.
  • Division of Radiology, Diagnostic Department, Geneva University Hospitals, Geneva, Switzerland. Electronic address: hicham.bouredoucen@hug.ch.

Zitieren

APA

Boudabbous, S., Branco, D. F., Tscholl, P. M., Delattre, B. M. A., Rubbia-Brandt, L., Bouredoucen, H., Poletti, P. A., Hannouche, D., Lövblad, K. O., & Kurz, F. T. (2026). Ultra-High-Field (7T) knee MRI: review of technical considerations and current evidence, with experience from an institutional clinical series. Magnetic Resonance Imaging, 110846. https://doi.org/10.1016/j.mri.2026.110846

Vancouver

Boudabbous S, Branco DF, Tscholl PM, Delattre BMA, Rubbia-Brandt L, Bouredoucen H, et al. Ultra-High-Field (7T) knee MRI: review of technical considerations and current evidence, with experience from an institutional clinical series. Magnetic Resonance Imaging. 2026:110846. doi:10.1016/j.mri.2026.110846

BibTeX
@article{Boudabbous2026,
  author = {Boudabbous, Sana and Branco, David Ferreira and Tscholl, Philippe M and Delattre, Bénédicte Marie Anne and Rubbia-Brandt, Laura and Bouredoucen, Hicham and Poletti, Pierre Alexandre and Hannouche, Didier and Lövblad, Karl-Olof and Kurz, Felix T},
  title = {Ultra-High-Field (7T) knee MRI: review of technical considerations and current evidence, with experience from an institutional clinical series},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  pages = {110846},
  doi = {10.1016/j.mri.2026.110846}
}
Kostenlos starten →