Ultra-high-field 5 T MRI for parotid gland assessment in Sjögren's syndrome: Improved image quality and reliable fat fraction quantification
Magnetic Resonance Imaging · 2026
DOI: 10.1016/j.mri.2026.110767 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Mengqi Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beijing Friendship Hospital, Capital Medical University, China. Hauptthemen laut MEDLINE: Sjogren's Syndrome, Parotid Gland, Magnetic Resonance Imaging, Adipose Tissue. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Ultra-high-field 5 T MRI systems offers potential advantages in signal-to-noise ratio(SNR) for visualizing fine anatomical structures. This prospective study aimed to assess the feasibility of parotid gland imaging in patients with Sjögren's syndrome (SS) at 5 T MRI and to compare image quality and fat fraction (FF) with between 5 T and 3 T MRI. METHODS: Thirty-one patients with SS underwent MRI examinations on both 3 T and 5 T scanners from October 2024 to August 2025. The sequences included transverse T1-weighted (T1W) sequence, transverse T2-weighted (T2W) fat-only, transverse T2-weighted (T2W) water-only, 3D MR sialography(MRS), and sequences for FF quantification: Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL-IQ) at 3 T/Fat Analysis & Calculation Technique (FACT3d) at 5 T. Image quality was assessed subjectively using a five-point Likert scale and objectively by calculating signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and the contrast ratio (CR). MRS sialography staging and parotid gland FF measurements were also performed. Statistical comparisons were made using paired t-tests, Wilcoxon signed-rank tests, Bland-Altman analysis, Pearson Correlation analysis and intraclass correlation coefficient (ICC). RESULTS: Compared with 3 T MRI, 5 T MRI demonstrated significantly superior subjective image quality scores, SNR, and CNR across all anatomical sequences (all p < 0.05), with the most pronounced improvement on T2WI. 5 T MRS showed a tendency to detect more advanced ductal changes and achieved significantly higher ductal CNR (all p < 0.05). FF measurements between 5 T and 3 T showed excellent agreement and a strong positive correlation (r = 0.981, p < 0.01). CONCLUSIONS: 5 T MRI provides markedly improved image quality for parotid gland assessment in SS while maintaining excellent consistency in FF quantification and sialography staging compared with 3 T MRI, highlighting its potential for detecting early-stage glandular changes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, China.
- Department of Rheumatology, Beijing Friendship Hospital, Capital Medical University, China.
- MR Research Collaboration, Shanghai United Imaging Healthcare Co., Ltd, China.
- Department of Rheumatology, Beijing Friendship Hospital, Capital Medical University, China. Electronic address: peal48@163.com.
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, China. Electronic address: qiaopenggang1226@163.com.
Zitieren
APA
Xu, M., Bai, X., Bai, M., Li, E., Yu, D., Yan, X., Zhou, M., & Qiao, P. G. (2026). Ultra-high-field 5 T MRI for parotid gland assessment in Sjögren's syndrome: Improved image quality and reliable fat fraction quantification. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110767
Vancouver
Xu M, Bai X, Bai M, Li E, Yu D, Yan X, et al. Ultra-high-field 5 T MRI for parotid gland assessment in Sjögren's syndrome: Improved image quality and reliable fat fraction quantification. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110767
BibTeX
@article{Xu2026,
author = {Xu, Mengqi and Bai, Xiaoyan and Bai, Mingxin and Li, Enhui and Yu, Dan and Yan, Xinyi and Zhou, Mingzhu and Qiao, Peng-Gang},
title = {Ultra-high-field 5 T MRI for parotid gland assessment in Sjögren's syndrome: Improved image quality and reliable fat fraction quantification},
journal = {Magnetic Resonance Imaging},
year = {2026},
doi = {10.1016/j.mri.2026.110767}
}
EUVIMED