Simultaneous acquisition of MR elastography, Dixon water–fat separation images, and CT-like bone contrast using a gradient-echo multi-echo sequence
Magnetic Resonance Imaging · 2026-09 · 131 · 110693
DOI: 10.1016/j.mri.2026.110693 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-09. Verfasst von Tomokazu Numano und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 1…. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Adipose Tissue, Magnetic Resonance Imaging, Bone and Bones. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Science and Technology Agency, Japan Science and Technology Corporation, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
This study proposes a unified imaging framework that enables simultaneous acquisition of MR elastography (MRE), Dixon-based water-fat separation images, and CT-like bone contrast within a single gradient-echo multi-echo sequence. A MEG-less multi-echo GRE acquisition was modified to incorporate three contrast mechanisms: the first echo was used for water-fat separation via a two-point Dixon method, MEG-like motion encoding generated by alternating readout gradients provided displacement sensitivity in later echoes, and in-phase TE echoes inherently present in the echo train were selectively combined to generate FRACTURE-style bone images. Seven healthy male volunteers were scanned at 3.0 T imager using a lumbar vibration actuator operating at 50 Hz. Water-fat selectivity exceeded leakage by more than an order of magnitude, demonstrating that Dixon separation was functionally preserved under the proposed framework. Shear modulus values of the bilateral psoas major muscles were consistent with previously reported MEG-less MRE results, with no significant side-to-side differences (p = 0.688). FRACTURE-style images showed consistent vertebral-body contrast across all volunteers. Vibration produced visible degradation in Dixon images, predominantly near the actuator. The proposed MEG-less multi-echo GRE approach allows concurrent acquisition of compositional, mechanical, and bone-related information without extending scan time or requiring additional sequences, offering a practical strategy for comprehensive musculoskeletal assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan.
- Department of Sports and Health Sciences, Faculty of Human Sciences, University of East Asia, Japan.
- Department of Frontier Health Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Japan.
- Department of Physical Therapy, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Japan.
Förderung
- Japan Science and Technology Agency
- Japan Science and Technology Corporation
- Japan Society for the Promotion of Science
Zitieren
APA
Numano, T., Ito, D., Habe, T., Ishihara, Y., Takamoto, K., Watanabe, M., Kamio, H., Yamada, K., Kawahara, Y., & Nishijo, H. (2026). Simultaneous acquisition of MR elastography, Dixon water–fat separation images, and CT-like bone contrast using a gradient-echo multi-echo sequence. Magnetic Resonance Imaging, 131, 110693. https://doi.org/10.1016/j.mri.2026.110693
Vancouver
Numano T, Ito D, Habe T, Ishihara Y, Takamoto K, Watanabe M, et al. Simultaneous acquisition of MR elastography, Dixon water–fat separation images, and CT-like bone contrast using a gradient-echo multi-echo sequence. Magnetic Resonance Imaging. 2026;131:110693. doi:10.1016/j.mri.2026.110693
BibTeX
@article{Numano2026,
author = {Numano, Tomokazu and Ito, Daiki and Habe, Tetsushi and Ishihara, Yoshito and Takamoto, Koichi and Watanabe, Masaru and Kamio, Hiroyo and Yamada, Keisuke and Kawahara, Yudai and Nishijo, Hisao},
title = {Simultaneous acquisition of MR elastography, Dixon water–fat separation images, and CT-like bone contrast using a gradient-echo multi-echo sequence},
journal = {Magnetic Resonance Imaging},
year = {2026},
volume = {131},
pages = {110693},
doi = {10.1016/j.mri.2026.110693}
}
EUVIMED