EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid 1 mm isotropic diffusion tensor imaging with denoising and improved parameter estimation for detecting focal hippocampal lesions in temporal lobe epilepsy

Pablo Stack-Sanchez, Christian Beaulieu, Donald W Gross

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110443 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Pablo Stack-Sanchez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Epilepsy, Temporal Lobe, Diffusion Tensor Imaging, Hippocampus. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consejo Nacional de Ciencia y Tecnología, Canada Research Chairs, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

While high resolution diffusion tensor imaging (DTI) at 1 mm isotropic can detect focal lesions of the hippocampus in temporal lobe epilepsy (TLE), faster acquisition times would facilitate potential clinical implementation. The purpose here is to assess different published denoising algorithms to overcome the low signal-to-noise ratio and accelerate 1 mm isotropic DTI of the human hippocampus at 3 T while maintaining diffusivity metric accuracy and image quality for focal lesion detection in TLE. The previously published 5.5 min protocol of 110 diffusion images per slice (10 directions × 10 averages and 10 b = 0 s/mm2) was assessed for subsets of 1-10 averages (same 10 directions) that were denoised using four algorithms that have been applied to other diffusion MRI datasets. In healthy controls, the variance-stabilizing transformation and optimal singular-value manipulation (VST) and Non-Local Spatial and Angular Matching (NLSAM) denoising greatly improved image quality while minimizing voxels with spurious extremes of fractional anisotropy (FA) or mean diffusivity (MD) down to 4 averages (i.e. 40 diffusion images and 4 b = 0 s/mm2) in healthy controls. The identification of focal lesions indicated by elevated MD and alterations of internal micro-architecture with only 4 averages were comparable to the full data set of 10 averages. Therefore, denoising of 1 mm isotropic DTI of the hippocampus enables a clinically feasible scan time of 2.2 min at 3 T that can be used for the detection of focal hippocampal lesions in TLE, as well as other neurological disorders such as multiple sclerosis, dementia and Alzheimer's disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Epilepsy, Temporal LobeDiffusion Tensor ImagingHippocampusHumansAlgorithmsAdultMaleFemaleSignal-To-Noise RatioAnisotropyImage Processing, Computer-AssistedMiddle AgedImage Interpretation, Computer-AssistedReproducibility of ResultsYoung Adult

Stichwörter der Autor:innen

DTIDenoisingHigh resolutionHippocampusTemporal lobe epilepsy

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada; Department of Radiology and Diagnostic Imaging, Faculty of Medicine and Dentistry, University of…
  • Division of Neurology, Faculty of Medicine & Dentistry, University of Alberta, Edmonton, Alberta, Canada. Electronic address: dwgross@ualberta.ca.

Förderung

  • Consejo Nacional de Ciencia y Tecnología
  • Canada Research Chairs
  • Canadian Institutes of Health Research

Zitieren

APA

Stack-Sanchez, P., Beaulieu, C., & Gross, D. W. (2025). Rapid 1 mm isotropic diffusion tensor imaging with denoising and improved parameter estimation for detecting focal hippocampal lesions in temporal lobe epilepsy. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110443

Vancouver

Stack-Sanchez P, Beaulieu C, Gross DW. Rapid 1 mm isotropic diffusion tensor imaging with denoising and improved parameter estimation for detecting focal hippocampal lesions in temporal lobe epilepsy. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110443

BibTeX
@article{StackSanchez2025,
  author = {Stack-Sanchez, Pablo and Beaulieu, Christian and Gross, Donald W},
  title = {Rapid 1 mm isotropic diffusion tensor imaging with denoising and improved parameter estimation for detecting focal hippocampal lesions in temporal lobe epilepsy},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110443}
}
Kostenlos starten →