Harmonized connectome resampling for variance in voxel sizes
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2025.110424 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Elyssa M McMaster und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA. Electronic address: elyssa.m.mcmaster@vanderbilt.edu. Hauptthemen laut MEDLINE: Connectome, Brain, Diffusion Tensor Imaging, White Matter. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NIA NIH HHS, NIDDK NIH HHS.
Abstract (Originalsprache)
Diffusion MRI (dMRI) fiber tractography presents exciting opportunities to deepen our knowledge of human brain connectivity and discover novel alterations in white matter. To date, there has been no comprehensive study characterizing the effect of dMRI voxel resolution on the resulting connectome for subject data. We assessed the statistical significance of graph measures derived from dMRI data by comparing connectomes from the same scans across different resolutions with 44 subjects (32 female) from the Human Connectome Project - Young Adult dataset (HCP-YA) with scan/rescan data (88 scans). We explored 15 isotropic and anisotropic resolutions, generated tractography and connectomes, and compared graph measures between each resolution and its nearest larger and smaller resolutions. Nearly all pairwise comparisons yielded statistically significant differences in graph measures (p ≤ 0.05, Wilcoxon Sign-Rank Test). Upon up sampling the 14 down sampled resolutions in 0.5 mm increments, we observed mitigation of the spatial sampling effect on both the tractography and the connectome's complex graph measures. To investigate translational impact, we resampled 22 subjects from HCP-YA to the resolutions of two major national studies and up-sampled this data back to 1 mm isotropic with different interpolation methods. Similarity in results improved with higher resolution, even after initial down-sampling. To ensure robust tractography and connectomes, resample data to 1 mm isotropic resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA. Electronic address: elyssa.m.mcmaster@vanderbilt.edu.
- Department of Computer Science, Vanderbilt University, Nashville, TN, USA.
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA.
- Vanderbilt Memory and Alzheimer's Center, Vanderbilt University School of Medicine, Nashville, TN, USA.
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
- Department of Computer Science, Université de Sherbrooke, Sherbrooke, QC, Canada.
Förderung
- NIBIB NIH HHS
- NIA NIH HHS
- NIDDK NIH HHS
- NCI NIH HHS
- NICHD NIH HHS
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
- National Institute on Aging
Zitieren
APA
McMaster, E. M., Newlin, N. R., Rudravaram, G., Saunders, A. M., Krishnan, A. R., Remedios, L. W., Kim, M. E., Xu, H., Yoon, J., Archer, D. B., Schilling, K. G., Rheault, F., Cutting, L. E., & Landman, B. A. (2025). Harmonized connectome resampling for variance in voxel sizes. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110424
Vancouver
McMaster EM, Newlin NR, Rudravaram G, Saunders AM, Krishnan AR, Remedios LW, et al. Harmonized connectome resampling for variance in voxel sizes. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110424
BibTeX
@article{McMaster2025,
author = {McMaster, Elyssa M and Newlin, Nancy R and Rudravaram, Gaurav and Saunders, Adam M and Krishnan, Aravind R and Remedios, Lucas W and Kim, Michael E and Xu, Hanliang and Yoon, Jongyeon and Archer, Derek B and Schilling, Kurt G and Rheault, François and Cutting, Laurie E and Landman, Bennett A},
title = {Harmonized connectome resampling for variance in voxel sizes},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2025.110424}
}
EUVIMED