EUVIMEDEUVIMED entdecken
Open Access

Advancement of an automatic segmentation pipeline for metallic artifact removal in post-surgical ACL MRI

Dominique A Barnes, Crystal J Murray, Janine Molino, Jillian E Beveridge, Ata M Kiapour, Martha M Murray, Braden C Fleming

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110417 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Dominique A Barnes und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI, USA; Rhode Island Hospital, Providence, RI, USA; Instit…. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Anterior Cruciate Ligament, Anterior Cruciate Ligament Injuries. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NIAMS NIH HHS, National Football League Players Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) has the potential to identify post-operative risk factors for re-tearing an anterior cruciate ligament (ACL) using a combination of imaging signal intensity (SI) and cross-sectional area measurements of the healing ACL. During surgery micro-debris can result from drilling the osseous tunnels for graft and/or suture insertion. The debris presents a limitation when using post-surgical MRI to assess reinjury risk as it causes rapid magnetic field variations during acquisition, leading to signal loss within a voxel. The present study demonstrates how K-means clustering can refine an automatic segmentation algorithm to remove the lost signal intensity values induced by the artifacts in the image. MRI data were obtained from 82 patients enrolled in three prospective clinical trials of ACL surgery. Constructive Interference in Steady State MRIs were collected at 6 months post-operation. Manual segmentation of the ACL with metallic artifacts removed served as the gold standard. The accuracy of the automatic ACL segmentations was compared using Dice coefficient, sensitivity, and precision. The performance of the automatic segmentation was comparable to manual segmentation (Dice coefficient = .81, precision = .81, sensitivity = .82). The normalized average signal intensity was calculated as 1.06 (±0.25) for the automatic and 1.04 (±0.23) for the manual segmentation, yielding a difference of 2%. These metrics emphasize the automatic segmentation model's ability to precisely capture ACL signal intensity while excluding artifact regions. The automatic artifact segmentation model described here could enhance qMRI's clinical utility by allowing for more accurate and time-efficient segmentations of the ACL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingAnterior Cruciate LigamentAnterior Cruciate Ligament InjuriesMetalsAnterior Cruciate Ligament ReconstructionImage Interpretation, Computer-AssistedHumansMaleAlgorithmsFemaleAdultReproducibility of ResultsSensitivity and SpecificityYoung Adult

Stichwörter der Autor:innen

ACLArtifactsMRIMachine Learning

Substanzen

Metals

Autor:innen und Institutionen

  • Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI, USA; Rhode Island Hospital, Providence, RI, USA; Institute for Biology, Engineering, and Medicine, Brown University, Providen…
  • Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI, USA; Rhode Island Hospital, Providence, RI, USA.
  • Department of Orthopaedics, Warren Alpert Medical School of Brown University, Providence, RI, USA; Brown University Health Biostatistics, Epidemiology, Research Design, & Informatics Core, Rhode Island Hospital, Provide…
  • Department of Orthopaedic Surgery and Sports Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.

Förderung

  • NIGMS NIH HHS
  • NIAMS NIH HHS
  • National Football League Players Association
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases
  • Harvard University
  • National Institutes of Health
  • NIH National Institute of General Medical Sciences
  • RIH Orthopaedic Foundation

Zitieren

APA

Barnes, D. A., Murray, C. J., Molino, J., Beveridge, J. E., Kiapour, A. M., Murray, M. M., & Fleming, B. C. (2025). Advancement of an automatic segmentation pipeline for metallic artifact removal in post-surgical ACL MRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110417

Vancouver

Barnes DA, Murray CJ, Molino J, Beveridge JE, Kiapour AM, Murray MM, et al. Advancement of an automatic segmentation pipeline for metallic artifact removal in post-surgical ACL MRI. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110417

BibTeX
@article{Barnes2025,
  author = {Barnes, Dominique A and Murray, Crystal J and Molino, Janine and Beveridge, Jillian E and Kiapour, Ata M and Murray, Martha M and Fleming, Braden C},
  title = {Advancement of an automatic segmentation pipeline for metallic artifact removal in post-surgical ACL MRI},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110417}
}
Kostenlos starten →