Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2024.110313 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Makoto Orii und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Iwate Medical University, Yahaba, Japan. Electronic address: kori931@gmail.com. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Cine, Heart Ventricles, Ventricular Function. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
OBJECTIVE: The total examination time can be reduced if high-quality two-dimensional (2D) cine images can be collected post-contrast to minimize non-scanning time prior to late gadolinium-enhanced imaging. This study aimed to assess the equivalency of the pre-and post-contrast performance of 2D deep learning-based highly accelerated cardiac cine (DL cine) imaging by evaluating the image quality and the quantification of biventricular volumes and function in the clinical setting. MATERIAL AND METHODS: Thirty patients (20 men, mean age 53.7 ± 17.8 years) underwent cardiac magnetic resonance on a 1.5 T scanner for clinical indications, and pre- and post-contrast DL cine images were acquired with a short-axis view. Image-quality was scored according to three main criteria: the blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed and compared between the pre- and post-contrast DL cine images. RESULTS: The actual median time of 2D DL cine acquisition was 38.4 ± 9.1 s. There were no significant differences in the image quality scores between pre- and post-contrast DL cine images (p > 0.05). In the volume and functional analysis, there was no significant difference in terms of biventricular EDV, ESV, SV, EF, and LVM (p > 0.05). CONCLUSIONS: The performance of 2D DL cine is equivalent before and after contrast injection for the assessment of image quality and ventricular function in the clinical setting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Iwate Medical University, Yahaba, Japan. Electronic address: kori931@gmail.com.
- Department of Radiology, Iwate Medical University, Yahaba, Japan.
- Department of Radiology Service, Iwate Medical University, Yahaba, Japan.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Orii, M., Sugawara, M., Sugawara, T., & Yoshioka, K. (2025). Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110313
Vancouver
Orii M, Sugawara M, Sugawara T, Yoshioka K. Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2024.110313
BibTeX
@article{Orii2025,
author = {Orii, Makoto and Sugawara, Momoko and Sugawara, Tsuyoshi and Yoshioka, Kunihiro},
title = {Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2024.110313}
}
EUVIMED