Use of multiparametric MRI to noninvasively assess iodinated contrast-induced acute kidney injury
Magnetic Resonance Imaging · 2024
DOI: 10.1016/j.mri.2024.110248 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Yongfang Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan 030000, Shanxi, China; Shanxi Key Laboratory of Intelligent Imagi…. Hauptthemen laut MEDLINE: Acute Kidney Injury, Contrast Media, Insulin-Like Growth Factor Binding Proteins, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanxi Province Science and Technology Department.
Abstract (Originalsprache)
PURPOSE: To gauge the utility of multiparametric MRI in characterizing pathologic changes after iodinated contrast-induced acute kidney injury (CI-AKI) in rats. METHODS: We randomly grouped 24 rats injected with 8 g iodine/kg of body weight (n = 6 each) and 6 rats injected with saline as controls. All rats underwent T1, T2 mapping and diffusion kurtosis imaging (DKI) after contrast injection at 0 (control), 1, 3, 7, 13 days. T1, T2, and mean kurtosis (MK) values were performed in renal outer/inner stripes of outer medulla (OSOM and ISOM) and cortex (CO), and their diagnosis performance for CI-AKI also been evaluated. Serum creatinine (SCr), insulin-like growth factor-binding protein 7 (IGFBP7), tissue inhibitor metalloproteinase 2 (TIMP-2), aquaporin-1 (AQP1), α-smooth muscle actin (α-SMA), and histologic indices were examined. RESULTS: Compared with controls, urinary concentrations of both TIMP-2 and IGFBP7 were obviously elevated from Day 1 to Day 13 (all p < 0.05). T2 values were significantly higher than control group for Days 1 and 3, and T1 and MK increased were more remarkable at all time points (Days 1-13) in CI-AKI (all p < 0.05) than control group. Changes in T1 and MK strongly correlated with renal injury scores of all anatomical compartments and with expression levels of AQP1 and moderately correlated with α-SMA. Changes in T2 values correlating moderately with renal scores of CO, ISOM and OSOM and AQP1. The MK obtained the highest area under the receiver operating characteristic (ROC) curve of 0.846 with a sensitivity of 70.8 % and specificity of 88.9 %. CONCLUSIONS: Combined use of multiparametric MRI could be a valid noninvasive method for comprehensive monitoring of CI-AKI. Among these parameters, MK may achieve the best diagnostic performance for CI-AKI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan 030000, Shanxi, China; Shanxi Key Laboratory of Intelligent Imaging, The First Hospital of Shanxi Medical University, Taiyuan, Shanxi P…
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan 030000, Shanxi, China.
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan 030000, Shanxi, China; Department of Medical Imaging, Shanxi Medical University, Taiyuan 030000, Shanxi, China.
- GE Healthcare, MR Research China, Beijing 100000, China. Electronic address: jinxia.guo@ge.com.
- GE Healthcare, MR Research China, Beijing 100000, China.
Förderung
- National Natural Science Foundation of China
- Shanxi Province Science and Technology Department
Zitieren
APA
Wang, Y., Wang, B., Qin, J., Yan, H., Chen, H., Guo, J., Wu, P. Y., & Wang, X. (2024). Use of multiparametric MRI to noninvasively assess iodinated contrast-induced acute kidney injury. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110248
Vancouver
Wang Y, Wang B, Qin J, Yan H, Chen H, Guo J, et al. Use of multiparametric MRI to noninvasively assess iodinated contrast-induced acute kidney injury. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.110248
BibTeX
@article{Wang2024,
author = {Wang, Yongfang and Wang, Bin and Qin, Jiangbo and Yan, Haili and Chen, Haoyuan and Guo, Jinxia and Wu, Pu-Yeh and Wang, Xiaochun},
title = {Use of multiparametric MRI to noninvasively assess iodinated contrast-induced acute kidney injury},
journal = {Magnetic Resonance Imaging},
year = {2024},
doi = {10.1016/j.mri.2024.110248}
}
EUVIMED