EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Spectro-ViT: A vision transformer model for GABA-edited MEGA-PRESS reconstruction using spectrograms

Gabriel Dias, Rodrigo Pommot Berto, Mateus Oliveira, Lucas Ueda, Sergio Dertkigil, Paula D P Costa, Amirmohammad Shamaei, Hanna Bugler, Roberto Souza, Ashley Harris, Leticia Rittner

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.110219 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Gabriel Dias und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil. Electronic address: g172441@dac.unicamp.br. Hauptthemen laut MEDLINE: gamma-Aminobutyric Acid, Magnetic Resonance Spectroscopy, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, CNPq, FAPESP.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the use of a Vision Transformer (ViT) for reconstructing GABA-edited Magnetic Resonance Spectroscopy (MRS) data from a reduced number of transients. Transients refer to the samples collected during an MRS acquisition by repeating the experiment to generate a signal of sufficient quality. Specifically, 80 transients were used instead of the typical 320 transients, aiming to reduce scan time. The 80 transients were pre-processed and converted into a spectrogram image representation using the Short-Time Fourier Transform (STFT). A pre-trained ViT, named Spectro-ViT, was fine-tuned and then tested using in-vivo GABA-edited MEGA-PRESS data. Its performance was compared against other pipelines in the literature using quantitative quality metrics and estimated metabolite concentration values, with the typical 320-transient scans serving as the reference for comparison. The Spectro-ViT model exhibited the best overall quality metrics among all other pipelines against which it was compared. The metabolite concentrations from Spectro-ViT's reconstructions for GABA+ achieved the best average R2 value of 0.67 and the best average Mean Absolute Percentage Error (MAPE) value of 9.68%, with no significant statistical differences found compared to the 320-transient reference. The code to reproduce this research is available at https://github.com/MICLab-Unicamp/Spectro-ViT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

gamma-Aminobutyric AcidMagnetic Resonance SpectroscopyAlgorithmsImage Processing, Computer-AssistedHumansFourier AnalysisBrainMagnetic Resonance Imaging

Stichwörter der Autor:innen

Deep learningGABA-edited MEGA-PRESSMRS denoisingVision transformer

Substanzen

gamma-Aminobutyric Acid

Autor:innen und Institutionen

  • School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil. Electronic address: g172441@dac.unicamp.br.
  • Department of Biomedical Engineering, University of Calgary, Calgary, Canada; Hotchkiss Brain Institute, University of Calgary, Calgary, Canada; Alberta Children's Hospital Research Institute, Calgary, Canada.
  • School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil.
  • School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil; Research and Development Center in Telecommunications, CPQD, Campinas, Brazil.
  • School of Medical Sciences, University of Campinas, Campinas, Brazil.
  • School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil; Artificial Intelligence Lab., Recod.ai, University of Campinas, Campinas, Brazil.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • CNPq
  • FAPESP
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Hotchkiss Brain Institute
  • Alberta Children's Hospital Research Institute

Zitieren

APA

Dias, G., Berto, R. P., Oliveira, M., Ueda, L., Dertkigil, S., Costa, P. D. P., Shamaei, A., Bugler, H., Souza, R., Harris, A., & Rittner, L. (2024). Spectro-ViT: A vision transformer model for GABA-edited MEGA-PRESS reconstruction using spectrograms. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110219

Vancouver

Dias G, Berto RP, Oliveira M, Ueda L, Dertkigil S, Costa PDP, et al. Spectro-ViT: A vision transformer model for GABA-edited MEGA-PRESS reconstruction using spectrograms. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.110219

BibTeX
@article{Dias2024,
  author = {Dias, Gabriel and Berto, Rodrigo Pommot and Oliveira, Mateus and Ueda, Lucas and Dertkigil, Sergio and Costa, Paula D P and Shamaei, Amirmohammad and Bugler, Hanna and Souza, Roberto and Harris, Ashley and Rittner, Leticia},
  title = {Spectro-ViT: A vision transformer model for GABA-edited MEGA-PRESS reconstruction using spectrograms},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.110219}
}
Kostenlos starten →