Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Fuxiang Zha und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, C…. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Uterine Neoplasms, Echo-Planar Imaging, Uterus. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the image quality of multiplexed sensitivity-encoding diffusion-weighted imaging (MUSE-DWI) and single-shot echo-planar imaging (SS-EPI-DWI) techniques in uterine MRI. METHODS: Eighty-eight eligible patients underwent MUSE-DWI and SS-EPI-DWI examinations simultaneously using a 3.0 T MRI system. Two radiologists independently performed quantitative and qualitative analysis of the two groups of images using a double-blind method. The weighted Kappa test was used to evaluate the interobserver agreement. Wilcoxon's rank sum test was used for qualitative parameters, and paired t-test was used for quantitative parameters. Spearman rank correlation analysis was used to obtained correlation between pathological results and mean apparent diffusion coefficient (ADC) value. RESULTS: The qualitative and quantitative analysis of the images by the two radiologists were in good or excellent agreement, with weighted kappa value ranging from 0.636 to 0.981. The scores of total subjective image quality (15.4 ± 0.99) and signal-to-noise ratio (158.99 ± 60.71) of MUSE-DWI were significantly higher than those of SS-EPI-DWI (12.93 ± 1.62 P < 0.001; 130.23 ± 48.29 P < 0.05). It effectively reduced image distortion and artifact, and had better lesion conspicuity. There was no significant difference in contrast-to-noise ratio score and average ADC values between the two DWI sequences. The average ADC values of the two DWI sequences were highest in the normal uterus group and lowest in the endometrial cancer group, with statistically significant differences among groups (P < 0.01). In addition, the average ADC values of the two DWI sequences were negatively correlated with the type of lesions, decreasing with the malignancy of the lesions (r = -0.805 P < 0.01, r = -0.815 P < 0.01). CONCLUSION: Compared to SS-EPI-DWI, MUSE-DWI can significantly reduce distortion, artifacts, and fuzziness in MRI of uterine lesions, which is more conducive to lesion detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingUterine NeoplasmsEcho-Planar ImagingUterusSignal-To-Noise RatioHumansFemaleMiddle AgedAdultObserver VariationAgedReproducibility of ResultsSensitivity and SpecificityImage Interpretation, Computer-AssistedDouble-Blind MethodImage Processing, Computer-AssistedImage Enhancement

Stichwörter der Autor:innen

Diffusion weighted imagingEndometrial cancerMagnetic resonance imagingMultiplexed sensitivity-encodingUterine lesions

Autor:innen und Institutionen

  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China.
  • MR Research, GE Healthcare, Beijing, China.
  • Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jiefang Avenue, Wuhan, Hubei, China. Electronic address: wss0331@126.com.

Zitieren

APA

Zha, F., Feng, C., Xu, J., Zou, Q., Li, J., Hu, D., Liu, W. V., Li, Z., & Wu, S. (2024). Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.03.003

Vancouver

Zha F, Feng C, Xu J, Zou Q, Li J, Hu D, et al. Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.03.003

BibTeX
@article{Zha2024,
  author = {Zha, Fuxiang and Feng, Cui and Xu, Jin and Zou, Qian and Li, Jiali and Hu, Daoyu and Liu, Weiyin Vivian and Li, Zhen and Wu, Sisi},
  title = {Evaluation of multiplexed sensitivity encoding diffusion-weighted imaging in detecting uterine lesions: Image quality optimization},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.03.003}
}
Kostenlos starten →