The effect of delay time after injecting gadobutrol on the diagnosis of endolymphatic hydrops
Magnetic Resonance Imaging · 2024-04 · 107 · 160-163
DOI: 10.1016/j.mri.2024.01.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024-04. Verfasst von Weidong Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China. Hauptthemen laut MEDLINE: Meniere Disease, Endolymphatic Hydrops, Organometallic Compounds. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: The aim of this study was to reduce the time delay between gadolinium injection and 3D-FLAIR (three-dimensional fluid-attenuated inversion recovery) MRI by using a single dose of intravenous gadobutrol in Menière's disease patients. METHODS: 17 patients diagnosed with definite unilateral Meniere's disease underwent 3D-FLAIR MRI scans at 2, 4, and 6 h post-intravenous administration of a single-dose of gadobutrol. The signal intensity ratio of bilateral inner ear, cochlear and vestibular hydrops was measured at 2 h, 4 h and 6 h, while the differences in signal intensity ratio and endolymphatic hydrops were evaluated at three time points. RESULTS: The cochlea, vestibule, and semicircular canal exhibit clear structural features with distinct perilymph-endolymph boundaries at 2 h, 4 h, and 6 h. The signal intensity ratio of the affected ear was significantly higher than that of the unaffected ear at 2 h, 4 h, and 6 h. The signal intensity ratio at 4 h and 6 h in both the affected and unaffected ears was significantly higher than that at 2 h, but there was no significant difference between 4 h and 6 h. Cochlear hydrops and vestibular hydrops show no significant differences at these time points, demonstrating excellent consistency. CONCLUSIONS: We have demonstrated that 3D-FLAIR images acquired 2 h after intravenous administration of a single-dose gadobutrol are of high quality and equally effective as those obtained at the conventional 4-h time point for diagnosing endolymphatic hydrops in Menière's disease. In clinical practice, the delay time can be safely shortened to 2 h.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China.
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China; Academy of Medical Sciences, Zhengzhou University, Zhengzhou, China.
- Department of Medical Imaging, Zhengzhou University People's Hospital & Henan Provincial People's Hospital, 7 Weiwu Road, 450000 Zhengzhou, China; Laboratory of Brain Science and Brain-Like Intelligence Technology, Inst…
Zitieren
APA
Zhang, W., Xie, J., & Wang, M. (2024). The effect of delay time after injecting gadobutrol on the diagnosis of endolymphatic hydrops. Magnetic Resonance Imaging, 107, 160-163. https://doi.org/10.1016/j.mri.2024.01.002
Vancouver
Zhang W, Xie J, Wang M. The effect of delay time after injecting gadobutrol on the diagnosis of endolymphatic hydrops. Magnetic Resonance Imaging. 2024;107:160-163. doi:10.1016/j.mri.2024.01.002
BibTeX
@article{Zhang2024,
author = {Zhang, Weidong and Xie, Jiapei and Wang, Meiyun},
title = {The effect of delay time after injecting gadobutrol on the diagnosis of endolymphatic hydrops},
journal = {Magnetic Resonance Imaging},
year = {2024},
volume = {107},
pages = {160--163},
doi = {10.1016/j.mri.2024.01.002}
}
EUVIMED