Automatic Rejection based on Tissue Signal (ARTS) for motion-corrected quantification of cerebral venous oxygenation in neonates and older adults
Magnetic Resonance Imaging · 2024-01 · 105 · 92-99
DOI: 10.1016/j.mri.2023.11.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024-01. Verfasst von Yifan Gou und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA. Hauptthemen laut MEDLINE: Brain, Alzheimer Disease. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NICHD NIH HHS, NINDS NIH HHS, NIA NIH HHS.
Themen: Gerontologische Pflege
Abstract (Originalsprache)
OBJECTIVE: Cerebral venous oxygenation (Yv) is a key parameter for the brain's oxygen utilization and has been suggested to be a valuable biomarker in various brain diseases including hypoxic ischemic encephalopathy in neonates and Alzheimer's disease in older adults. T2-Relaxation-Under-Spin-Tagging (TRUST) MRI is a widely used technique to measure global Yv level and has been validated against gold-standard PET. However, subject motion during TRUST MRI scan can introduce considerable errors in Yv quantification, especially for noncompliant subjects. The aim of this study was to develop an Automatic Rejection based on Tissue Signal (ARTS) algorithm for automatic detection and exclusion of motion-contaminated images to improve the precision of Yv quantification. METHODS: TRUST MRI data were collected from a neonatal cohort (N = 37, 16 females, gestational age = 39.12 ± 1.11 weeks, postnatal age = 1.89 ± 0.74 days) and an older adult cohort (N = 223, 134 females, age = 68.02 ± 9.01 years). Manual identification of motion-corrupted images was conducted for both cohorts to serve as a gold-standard. 9.3% of the images in the neonatal datasets and 0.4% of the images in the older adult datasets were manually identified as motion-contaminated. The ARTS algorithm was trained using the neonatal datasets. TRUST Yv values, as well as the estimation uncertainty (ΔR2) and test-retest coefficient-of-variation (CoV) of Yv, were calculated with and without ARTS motion exclusion. The ARTS algorithm was tested on datasets of older adults: first on the original adult datasets with little motion, and then on simulated adult datasets where the percentage of motion-corrupted images matched that of the neonatal datasets. RESULTS: In the neonatal datasets, the ARTS algorithm exhibited a sensitivity of 0.95 and a specificity of 0.97 in detecting motion-contaminated images. Compared to no motion exclusion, ARTS significantly reduced the ΔR2 (median = 3.68 Hz vs. 4.89 Hz, P = 0.0002) and CoV (median = 2.57% vs. 6.87%, P = 0.0005) of Yv measurements. In the original older adult datasets, the sensitivity and specificity of ARTS were 0.70 and 1.00, respectively. In the simulated adult datasets, ARTS demonstrated a sensitivity of 0.91 and a specificity of 1.00. Additionally, ARTS significantly reduced the ΔR2 compared to no motion exclusion (median = 2.15 Hz vs. 3.54 Hz, P < 0.0001). CONCLUSION: ARTS can improve the reliability of Yv estimation in noncompliant subjects, which may enhance the utility of Yv as a biomarker for brain diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Department of Pediatrics, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- Center for Imaging Science, Johns Hopkins University Whiting School of Engineering, Baltimore, MD, USA.
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA; The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA;…
Förderung
- NICHD NIH HHS
- NINDS NIH HHS
- NIA NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Gou, Y., Golden, W. C., Lin, Z., Shepard, J., Tekes, A., Hu, Z., Li, X., Oishi, K., Albert, M., Lu, H., Liu, P., & Jiang, D. (2024). Automatic Rejection based on Tissue Signal (ARTS) for motion-corrected quantification of cerebral venous oxygenation in neonates and older adults. Magnetic Resonance Imaging, 105, 92-99. https://doi.org/10.1016/j.mri.2023.11.008
Vancouver
Gou Y, Golden WC, Lin Z, Shepard J, Tekes A, Hu Z, et al. Automatic Rejection based on Tissue Signal (ARTS) for motion-corrected quantification of cerebral venous oxygenation in neonates and older adults. Magnetic Resonance Imaging. 2024;105:92-99. doi:10.1016/j.mri.2023.11.008
BibTeX
@article{Gou2024,
author = {Gou, Yifan and Golden, W Christopher and Lin, Zixuan and Shepard, Jennifer and Tekes, Aylin and Hu, Zhiyi and Li, Xin and Oishi, Kumiko and Albert, Marilyn and Lu, Hanzhang and Liu, Peiying and Jiang, Dengrong},
title = {Automatic Rejection based on Tissue Signal (ARTS) for motion-corrected quantification of cerebral venous oxygenation in neonates and older adults},
journal = {Magnetic Resonance Imaging},
year = {2024},
volume = {105},
pages = {92--99},
doi = {10.1016/j.mri.2023.11.008}
}
EUVIMED