Evaluation of methemoglobin as an intravascular contrast agent: T1 relaxation time effect in a rabbit model
Magnetic Resonance Imaging · 2023-11 · 103 · 1-7
DOI: 10.1016/j.mri.2023.06.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2023-11. Verfasst von Seong-Eun Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA. Electronic address: seongeun.kim@hsc…. Hauptthemen laut MEDLINE: Methemoglobin, Contrast Media. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, National Center for Advancing Translational Sciences, National Institutes of Health.
Abstract (Originalsprache)
OBJECTIVE: Alternative contrast agents for MRI are needed for individuals who may respond adversely to gadolinium, and need an intravascular agent for specific indications. One potential contrast agent is intracellular methemoglobin, a paramagnetic molecule that is normally present in small amounts in red blood cells. An animal model was used to determine whether methemoglobin modulation with intravenous sodium nitrite transiently changes the T1 relaxation of blood. METHODS: Four adult New Zealand white rabbits were treated with 30 mg intravenous sodium nitrite. 3D TOF and 3D MPRAGE images were acquired before (baseline) and after methemoglobin modulation. T1 of blood was measured with 2D ss EPl acquisitions with inversion recovery preparation performed at two-minute intervals up to 30 min. T1 maps were calculated by fitting the signal recovery curve within major blood vessels. RESULTS: Baseline T1 was 1758 ± 53 ms in carotid arteries and 1716 ± 41 ms in jugular veins. Sodium nitrite significantly changed intravascular T1 relaxation. The mean minimum value of T1 was 1126 ± 28 ms in carotid arteries 8 to 10 min after the injection of sodium nitrite. The mean minimum value of T1 was 1171 ± 52 ms in jugular veins 10 to 14 min after the injection of sodium nitrite. Arterial and venous T1 recovered to baseline after a period of 30 min. CONCLUSION: Methemoglobin modulation produces intravascular contrast on T1-weighted MRI in vivo. Additional studies are needed to safely optimize methemoglobin modulation and sequence parameters for maximal tissue contrast.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA. Electronic address: seongeun.kim@hsc.utah.edu.
- Utah Center for Advanced Imaging Research, Department of Radiology, University of Utah, Salt Lake City, UT, USA.
- Department of Pediatrics, University of Utah, Salt Lake City, UT, USA.
Förderung
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
- National Institutes of Health
Zitieren
APA
Kim, S. E., McNally, J. S., Alexander, M. D., Zabriskie, M. S., Parker, D. L., & Day, R. W. (2023). Evaluation of methemoglobin as an intravascular contrast agent: T1 relaxation time effect in a rabbit model. Magnetic Resonance Imaging, 103, 1-7. https://doi.org/10.1016/j.mri.2023.06.018
Vancouver
Kim SE, McNally JS, Alexander MD, Zabriskie MS, Parker DL, Day RW. Evaluation of methemoglobin as an intravascular contrast agent: T1 relaxation time effect in a rabbit model. Magnetic Resonance Imaging. 2023;103:1-7. doi:10.1016/j.mri.2023.06.018
BibTeX
@article{Kim2023,
author = {Kim, Seong-Eun and McNally, J Scott and Alexander, Matthew D and Zabriskie, Matthew S and Parker, Dennis L and Day, Ronald W},
title = {Evaluation of methemoglobin as an intravascular contrast agent: T1 relaxation time effect in a rabbit model},
journal = {Magnetic Resonance Imaging},
year = {2023},
volume = {103},
pages = {1--7},
doi = {10.1016/j.mri.2023.06.018}
}
EUVIMED