EUVIMEDEUVIMED entdecken
Crossref

Improved differentiation between stage I-II endometrial carcinoma and endometrial polyp with combination of APTw and IVIM MR imaging

Xing Meng, Shifeng Tian, Qinhe Zhang, Lihua Chen, Liangjie Lin, Jin Li, Zhiwei Shen, Jiazheng Wang, Yi Zhang, Qingwei Song, Ailian Liu

Magnetic Resonance Imaging · 2023

DOI: 10.1016/j.mri.2023.04.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2023. Verfasst von Xing Meng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China; Dalian Women and Children's Medi…. Hauptthemen laut MEDLINE: Protons, Endometrial Neoplasms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To assess the value of amide proton transfer weighted (APTw) combined with intra-voxel incoherent motion (IVIM) imaging in differential diagnosis of stage I-II endometrial carcinoma (EC) and endometrial polyp (EP). METHODS: A total of 53 female patients (37 cases with EC and 16 cases with EP) confirmed by surgical resection or biopsy from June 2019 to Jan. 2022 were retrospectively reviewed. All patients underwent 3.0 T magnetic resonance imaging (MRI) examination including diffusion weighted imaging (DWI), APTw and IVIM scans. The pure diffusion coefficient (D), pseudo-diffusion coefficient (D⁎), perfusion fraction (f), apparent diffusion coefficient (ADC) and APT values were independently measured by two observers. Intra-class correlation coefficients (ICC) were used to test the consistency of measurements by the two observers. Mann-Whitney U test was performed to analyze the difference of each parameter between EC and EP groups. Receiver operator characteristic (ROC) analysis was performed, and the Delong test was used for ROC curve comparison. Pearson's correlation analysis was used to assess the correlation between APTw and IVIM parameters. RESULTS: There was no significant difference in clinical manifestations between the two groups (P > 0.05). APT and D⁎ values of the EC group were significantly higher than those of the EP group [APT: 2.64 ± 0.50% vs. 2.05 ± 0.58%; and D⁎: (54.06 ± 36.06) × 10-3 mm2/s vs. (30.54 ± 16.67) × 10-3 mm2/s]. D, f and ADC values of EC group were significantly lower than those of EP group [D: 0.62(0.53,0.76) × 10-3 mm2/s vs. (1.45 ± 0.48) × 10-3 mm2/s; f: 22.18 ± 8.08% vs. 30.80 ± 8.92%; and ADC: (0.88 ± 0.16) × 10-3 mm2/s vs. (1.57 ± 0.43) × 10-3 mm2/s]. The area under ROC curves were observed as: AUC (IVIM+APT) > AUC (D) > AUC (ADC) > AUC (APT) > AUC (f) > AUC (D⁎). Delong test suggested statistical significance between AUC by APT and D, D and D⁎, D and f, D⁎ and ADC, APT and com(IVIM+APT), D⁎ and com(IVIM+APT), as well as f and com(IVIM+APT). No significant correlation between the APT and IVIM parameters was observed in either EC or EP group. CONCLUSION: Both APT and IVIM parameters showed statistical differences between EC and EP. With combination of APT and IVIM parameters, the diagnostic accuracy between EC and EP can be significantly improved.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProtonsEndometrial NeoplasmsHumansFemaleRetrospective StudiesAmidesMagnetic Resonance ImagingDiffusion Magnetic Resonance ImagingMotion

Stichwörter der Autor:innen

Amide proton transfer weightedEndometrial carcinomaEndometrial polypIntra-voxel incoherent motionMagnetic resonance imaging

Substanzen

ProtonsAmides

Autor:innen und Institutionen

  • Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China; Dalian Women and Children's Medical Group, Dalian, Liaoning 116033, China.
  • Department of Radiology, the First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China.
  • Advanced Technical Support, Philips Healthcare, Beijing 100600, China. Electronic address: liangjie.lin@philips.com.
  • Advanced Technical Support, Philips Healthcare, Beijing 100600, China. Electronic address: Jin.LI_1@philips.com.
  • Advanced Technical Support, Philips Healthcare, Beijing 100600, China. Electronic address: jerry.shen@philips.com.
  • Advanced Technical Support, Philips Healthcare, Beijing 100600, China. Electronic address: jiazheng.wang@philips.com.

Zitieren

APA

Meng, X., Tian, S., Zhang, Q., Chen, L., Lin, L., Li, J., Shen, Z., Wang, J., Zhang, Y., Song, Q., & Liu, A. (2023). Improved differentiation between stage I-II endometrial carcinoma and endometrial polyp with combination of APTw and IVIM MR imaging. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2023.04.001

Vancouver

Meng X, Tian S, Zhang Q, Chen L, Lin L, Li J, et al. Improved differentiation between stage I-II endometrial carcinoma and endometrial polyp with combination of APTw and IVIM MR imaging. Magnetic Resonance Imaging. 2023. doi:10.1016/j.mri.2023.04.001

BibTeX
@article{Meng2023,
  author = {Meng, Xing and Tian, Shifeng and Zhang, Qinhe and Chen, Lihua and Lin, Liangjie and Li, Jin and Shen, Zhiwei and Wang, Jiazheng and Zhang, Yi and Song, Qingwei and Liu, Ailian},
  title = {Improved differentiation between stage I-II endometrial carcinoma and endometrial polyp with combination of APTw and IVIM MR imaging},
  journal = {Magnetic Resonance Imaging},
  year = {2023},
  doi = {10.1016/j.mri.2023.04.001}
}
Kostenlos starten →