EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of plate counting with flow cytometry, using four different fluorescent dye techniques, for the enumeration of Bacillus cereus in milk

Ben T Somerton, Brooke L Morgan

Journal of Microbiological Methods · 2024

DOI: 10.1016/j.mimet.2024.106978 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Microbiological Methods, 2024. Verfasst von Ben T Somerton und 1 weiteren Autor:innen. Beteiligte Einrichtung: Fonterra Research & Development Centre, Fonterra, Palmerston North, New Zealand. Electronic address: Ben.Somerton@fonterra.com. Hauptthemen laut MEDLINE: Bacillus cereus, Milk, Flow Cytometry, Fluorescent Dyes. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to compare the performance of flow cytometry methods with plate counting for the enumeration of bacteria, using Bacillus cereus as a model organism. It was found that the cFDA-propidium iodide, CellROX™ Green-propidium iodide, and DiOC2 dye techniques had similar accuracy to plate counting, while the SYTO 24-propidium iodide dye technique was not as accurate. The four dye techniques had comparable precision to plate counting, with the CellROX™ Green-propidium iodide dye having the greatest precision. The consistency of the position and shape of the cell clusters on the flow cytometry plots, and the extent of separation of the cell from background clusters, was greatest with the DiOC2 and CellROX™ Green-propidium iodide dyes. Furthermore, the DiOC2 and CellROX™ Green-propidium iodide dyes performed well, even when a sample was measured containing reconstituted whole milk powder at a 10-1 dilution, without the use of sample preparation to specifically remove the milk constituents prior to measurement. Given gating of only one cell cluster was required to be managed with the DiOC2 dye, to determine the viable number of cells, it was found that the DiOC2 dye had the greatest ease-of-use. Overall, results indicated that the DiOC2 dye is an ideal candidate for the enumeration of viable bacteria in dairy samples on a high-throughput, routine basis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bacillus cereusMilkFlow CytometryFluorescent DyesAnimalsColony Count, MicrobialBacterial LoadPropidiumStaining and Labeling

Stichwörter der Autor:innen

BacteriaCellROX™ greenDiOC(2)Flow cytometryMilk qualityPropidium iodide

Substanzen

Fluorescent DyesPropidium

Autor:innen und Institutionen

  • Fonterra Research & Development Centre, Fonterra, Palmerston North, New Zealand. Electronic address: Ben.Somerton@fonterra.com.
  • Fonterra Research & Development Centre, Fonterra, Palmerston North, New Zealand.

Zitieren

APA

Somerton, B. T., & Morgan, B. L. (2024). Comparison of plate counting with flow cytometry, using four different fluorescent dye techniques, for the enumeration of Bacillus cereus in milk. Journal of Microbiological Methods. https://doi.org/10.1016/j.mimet.2024.106978

Vancouver

Somerton BT, Morgan BL. Comparison of plate counting with flow cytometry, using four different fluorescent dye techniques, for the enumeration of Bacillus cereus in milk. Journal of Microbiological Methods. 2024. doi:10.1016/j.mimet.2024.106978

BibTeX
@article{Somerton2024,
  author = {Somerton, Ben T and Morgan, Brooke L},
  title = {Comparison of plate counting with flow cytometry, using four different fluorescent dye techniques, for the enumeration of Bacillus cereus in milk},
  journal = {Journal of Microbiological Methods},
  year = {2024},
  doi = {10.1016/j.mimet.2024.106978}
}
Kostenlos starten →