EUVIMEDEUVIMED entdecken
Crossref

Development of a closed-tube, calcein-based loop-mediated isothermal amplification assay to detect Salmonella spp. in raw meat samples

Khristine B Balaga, Rance Derrick N Pavon, Alyzza Marie B Calayag, Christine Aubrey C Justo, Davin Edric V Adao, Windell L Rivera

Journal of Microbiological Methods · 2024

DOI: 10.1016/j.mimet.2024.106922 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Microbiological Methods, 2024. Verfasst von Khristine B Balaga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pathogen-Host-Environment Interactions Research Laboratory, Institute of Biology, College of Science, University of the Philippines Diliman, Quezon C…. Hauptthemen laut MEDLINE: Food Microbiology, Nucleic Acid Amplification Techniques, Fluoresceins, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Foodborne pathogens compromise food safety and public health, and Salmonella spp. are among the major pathogenic bacteria that cause outbreaks worldwide. Proper surveillance through timely and cost-effective detection methods across the food animal production chain is crucial to prevent Salmonella outbreaks and agricultural losses. Traditional culture methods are labor- and resource-intensive, with lengthy turnaround times. Meanwhile, conventional molecular tools, such as PCR and qPCR, are expensive and require technical skills and equipment. Loop-mediated isothermal amplification (LAMP) is a simple, rapid, inexpensive, highly sensitive, and specific molecular assay that does not require expensive equipment. Hence, this study developed and optimized a closed-tube, calcein-based LAMP assay to detect Salmonella using the invA gene and performed evaluation and validation against conventional PCR. The LAMP assay showed high specificity and sensitivity. It showed 10-fold higher sensitivity than conventional PCR, at

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Food MicrobiologyNucleic Acid Amplification TechniquesFluoresceinsMolecular Diagnostic TechniquesAnimalsCattleSalmonellaMeatSensitivity and Specificity

Stichwörter der Autor:innen

Closed-tubeLoop-mediated isothermal amplification assayPolymerase chain reactionRaw meat samplesSalmonella enterica

Substanzen

fluorexonFluoresceins

Autor:innen und Institutionen

  • Pathogen-Host-Environment Interactions Research Laboratory, Institute of Biology, College of Science, University of the Philippines Diliman, Quezon City 1101, Philippines.
  • Pathogen-Host-Environment Interactions Research Laboratory, Institute of Biology, College of Science, University of the Philippines Diliman, Quezon City 1101, Philippines. Electronic address: wlrivera@science.upd.edu.ph.

Zitieren

APA

Balaga, K. B., Pavon, R. D. N., Calayag, A. M. B., Justo, C. A. C., Adao, D. E. V., & Rivera, W. L. (2024). Development of a closed-tube, calcein-based loop-mediated isothermal amplification assay to detect Salmonella spp. in raw meat samples. Journal of Microbiological Methods. https://doi.org/10.1016/j.mimet.2024.106922

Vancouver

Balaga KB, Pavon RDN, Calayag AMB, Justo CAC, Adao DEV, Rivera WL. Development of a closed-tube, calcein-based loop-mediated isothermal amplification assay to detect Salmonella spp. in raw meat samples. Journal of Microbiological Methods. 2024. doi:10.1016/j.mimet.2024.106922

BibTeX
@article{Balaga2024,
  author = {Balaga, Khristine B and Pavon, Rance Derrick N and Calayag, Alyzza Marie B and Justo, Christine Aubrey C and Adao, Davin Edric V and Rivera, Windell L},
  title = {Development of a closed-tube, calcein-based loop-mediated isothermal amplification assay to detect Salmonella spp. in raw meat samples},
  journal = {Journal of Microbiological Methods},
  year = {2024},
  doi = {10.1016/j.mimet.2024.106922}
}
Kostenlos starten →