EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

An improved MTT colorimetric method for rapid viable bacteria counting

Wenliang Xu, Danxia Shi, Kuanmin Chen, Jon Palmer, David G Popovich

Journal of Microbiological Methods · 2023-11 · 214 · 106830

DOI: 10.1016/j.mimet.2023.106830 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Microbiological Methods, 2023-11. Verfasst von Wenliang Xu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Food and Advanced Technology, Massey University, Palmerston North 4410, New Zealand. Hauptthemen laut MEDLINE: Colorimetry, Escherichia coli. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay has been employed in the analysis of bacterial growth. In comparison to experiments conducted on mammalian cells, the MTT bacterial assay encounters a greater number of interfering factors and obstacles that impact the accuracy of results. In this study, we have elucidated an improved MTT assay protocol and put forth an equation that establishes a correlation between colony-forming units (CFU) and the amount of formazan converted by the bacteria, drawing upon the fundamental principle of the MTT assay. This equation is represented as CFU=kF. Furthermore, we have explicated a methodology to determine the scale factor "k" by employing S. aureus and E. coli as illustrative examples. The findings indicate that S. aureus and E. coli reduce MTT by a cyclic process, from which the optimal reduction time at room temperature was determined to be approximately 30 mins. Furthermore, individual E. coli exhibits an MTT reduction capacity approximately four times greater than that of S. aureus. HPLC analysis proves to be the most accurate method for mitigating interferences during the dissolution and quantification of formazan. Additionally, this study has identified a new constraint related to the narrow linear range (0-125 μg/mL) of formazan concentration-absorbance and has presented strategies to circumvent this limitation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorimetryEscherichia coliAnimalsFormazansStaphylococcus aureusTetrazolium SaltsMammals

Stichwörter der Autor:innen

Escherichia coliFormazanHPLCMTT bacterial assayStaphylococcus aureusViable count

Substanzen

FormazansTetrazolium Salts

Autor:innen und Institutionen

  • School of Food and Advanced Technology, Massey University, Palmerston North 4410, New Zealand.
  • School of Food and Advanced Technology, Massey University, Palmerston North 4410, New Zealand. Electronic address: D.G.Popovich@massey.ac.nz.

Zitieren

APA

Xu, W., Shi, D., Chen, K., Palmer, J., & Popovich, D. G. (2023). An improved MTT colorimetric method for rapid viable bacteria counting. Journal of Microbiological Methods, 214, 106830. https://doi.org/10.1016/j.mimet.2023.106830

Vancouver

Xu W, Shi D, Chen K, Palmer J, Popovich DG. An improved MTT colorimetric method for rapid viable bacteria counting. Journal of Microbiological Methods. 2023;214:106830. doi:10.1016/j.mimet.2023.106830

BibTeX
@article{Xu2023,
  author = {Xu, Wenliang and Shi, Danxia and Chen, Kuanmin and Palmer, Jon and Popovich, David G},
  title = {An improved MTT colorimetric method for rapid viable bacteria counting},
  journal = {Journal of Microbiological Methods},
  year = {2023},
  volume = {214},
  pages = {106830},
  doi = {10.1016/j.mimet.2023.106830}
}
Kostenlos starten →