EUVIMEDEUVIMED entdecken
Crossref

Time synchronization of LED excitation source and dual-camera for quantitative FRET imaging

Hai Wen, Huan Zuo, Xinghong Cai, Xinlei Li, Zhengfei Zhuang, Tongsheng Chen

Micron · 2025

DOI: 10.1016/j.micron.2025.103870 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micron, 2025. Verfasst von Hai Wen und 5 weiteren Autor:innen. Beteiligte Einrichtung: MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering…. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Special Project for Research and Development in Key areas of Guangdong Province, Songshan Lake Materials Laboratory.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multi-wavelength LED light source has been widely used as excitation source in fluorescence microscopy. This study presents a six-wavelength LED excitation source that integrates an internal time synchronization control mechanism, enabling high-precision synchronization between LED excitation and dual-camera imaging without requiring additional control hardware. The control system is built around an STM32F429 microcontroller and employs a hardware-triggered synchronization strategy specifically designed for quantitative fluorescence resonance energy transfer (FRET) imaging. By incorporating this excitation source into a dual-channel fluorescence microscope, we minimized the excitation-exposure timing discrepancy to 10μs, effectively reducing unnecessary exposure and mitigating photobleaching. To assess system performance, we conducted quantitative FRET analysis in living cells expressing different standard FRET plasmids. Experimental results demonstrated that during time-lapse FRET analysis, the synchronization system reduced photobleaching-induced deviations in FRET efficiency (ED) and acceptor-to-donor ratio (Rc) from 18.8% and 15.8% to 5.6% and 2.6%, respectively, thereby enhancing the reliability of FRET quantification. As FRET is widely used to study protein interactions, conformational changes, and signal transduction pathways, this system improves the accuracy of dynamic molecular measurements in live-cell imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescence Resonance Energy TransferMicroscopy, FluorescenceHumansPhotobleaching

Stichwörter der Autor:innen

FRETFluorescence microscopyHardware triggerLED excitation sourceSynchronization control

Autor:innen und Institutionen

  • MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China; Guangdong Pr…

Förderung

  • National Natural Science Foundation of China
  • Special Project for Research and Development in Key areas of Guangdong Province
  • Songshan Lake Materials Laboratory
  • Natural Science Foundation of Guangdong Province

Zitieren

APA

Wen, H., Zuo, H., Cai, X., Li, X., Zhuang, Z., & Chen, T. (2025). Time synchronization of LED excitation source and dual-camera for quantitative FRET imaging. Micron. https://doi.org/10.1016/j.micron.2025.103870

Vancouver

Wen H, Zuo H, Cai X, Li X, Zhuang Z, Chen T. Time synchronization of LED excitation source and dual-camera for quantitative FRET imaging. Micron. 2025. doi:10.1016/j.micron.2025.103870

BibTeX
@article{Wen2025,
  author = {Wen, Hai and Zuo, Huan and Cai, Xinghong and Li, Xinlei and Zhuang, Zhengfei and Chen, Tongsheng},
  title = {Time synchronization of LED excitation source and dual-camera for quantitative FRET imaging},
  journal = {Micron},
  year = {2025},
  doi = {10.1016/j.micron.2025.103870}
}
Kostenlos starten →