Automation in wastewater-based epidemiology for efficient analysis of 123 multi-class illicit drugs: evaluating method eco-friendliness and practicality
Microchemical Journal · 2025-11 · 218 · 115270
DOI: 10.1016/j.microc.2025.115270 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchemical Journal, 2025-11. Verfasst von Bhaskar Karubothula und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The performance of automated sample preparation using the modular Biomek i7 workstation was evaluated for analyzing 123 illicit drugs in wastewater. The method underwent extensive development, including optimization of UPLC-MS/MS parameters, assessment of compound stability and extraction efficiency using three types of SPE cartridges. Stability study of 60 days showed that all analytes remained stable at -25 ± 3 °C, but storage at 6 ± 2 °C affected the stability of 30 analytes. Extraction efficiency trials revealed that the order of suitability for SPE cartridges is, Mixed-Mode Cation Exchange (MCX) > Hydrophilic-Lipophilic Balance (HLB) > Mixed-Mode Anion Exchange (MAX). The method demonstrated specificity for all targeted IDs, with the max interfering peak for Pregabalin reaching 8.01% of the target limit of quantification (LOQ). The method met ±20% matrix effect tolerance for 114 IDs, while 6 IDs showed signal suppression and 5 exhibited signal enhancement. The 8-point procedural calibration curve, (six-point for 9 IDs), prepared using automated robotic extraction has demonstrated linearity across the tested range. Spiked study at LQC, MQC, and HQC levels, n=6, repeated on three separate occasions, showed that 91.6% of observations had a relative standard deviation (RSD) below 10%, 7.8% fell within the 10-15% RSD range, and 0.54% were between 15-20% RSD. Regarding mean % recovery, 95.66% of observations were within 90-110%, 2.71% ranged between 80-90%, and 1.62% were between 110-130%. The method met validation requirements, showed reliability in Intra-Laboratory Comparison with an acceptable "z" score, and received high ratings for greenness (GAPI, AGREE) and practicality (BAGI).
Zitieren
APA
Karubothula, B., Cheerala, V., Shinde, D., Tadala, R., Kota, V. V., Salem, S. B., Elamin, W., & Brudecki, G. (2025). Automation in wastewater-based epidemiology for efficient analysis of 123 multi-class illicit drugs: evaluating method eco-friendliness and practicality. Microchemical Journal, 218, 115270. https://doi.org/10.1016/j.microc.2025.115270
Vancouver
Karubothula B, Cheerala V, Shinde D, Tadala R, Kota VV, Salem SB, et al. Automation in wastewater-based epidemiology for efficient analysis of 123 multi-class illicit drugs: evaluating method eco-friendliness and practicality. Microchemical Journal. 2025;218:115270. doi:10.1016/j.microc.2025.115270
BibTeX
@article{Karubothula2025,
author = {Karubothula, Bhaskar and Cheerala, Vishnu and Shinde, Dnyaneshwar and Tadala, Raghu and Kota, Veera Venkataramana and Salem, Samara Bin and Elamin, Wael and Brudecki, Grzegorz},
title = {Automation in wastewater-based epidemiology for efficient analysis of 123 multi-class illicit drugs: evaluating method eco-friendliness and practicality},
journal = {Microchemical Journal},
year = {2025},
volume = {218},
pages = {115270},
doi = {10.1016/j.microc.2025.115270}
}
EUVIMED