EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A straightforward Py-GC/MS methodology for quantification of microplastics in tap water

Alexander Ccanccapa-Cartagena, Anandu Nair Gopakumar, Maryam Salehi

MethodsX · 2025-06 · 14 · 103173

DOI: 10.1016/j.mex.2025.103173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MethodsX, 2025-06. Verfasst von Alexander Ccanccapa-Cartagena und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO, USA. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Institute of Food and Agriculture, US Department of Agriculture, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces a cost-effective and streamlined Pyrolysis Gas Chromatography-Mass Spectrometry (Py-GC/MS) methodology for detecting and quantifying microplastics in tap water, focusing on seven common polymers. Unlike conventional approaches relying on expensive pyrolyzate libraries, this method identifies pyrolysis fragments by matching their m/z values with commercially available mass spectral libraries (Wiley Registry 12th Edition/NIST 2020) and confirms findings using pure polymer standards. Recovery was evaluated using two approaches, demonstrating that analysis of the entire filter provided more accurate results compared to extrapolation from subsections. The method exhibited excellent linearity for all targeted polymers (R² > 0.996) and achieved detection limits as low as 0.01 µg for polystyrene (PS) and up to 2.59 µg for polyethylene (PE). Application to tap water samples revealed consistent detection of PS, ranging from 2.532 to 2.571 ng/L in morning samples and 0.867 to 1.540 ng/L in afternoon samples, with polypropylene and PE below the limit of quantification (

Schlagwörter

Stichwörter der Autor:innen

GC–MSMicroplasticsPlastic pollutionPy-GC/MS workflow for MPs analysisPyrolysisTap water

Autor:innen und Institutionen

  • Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO, USA.
  • Missouri Water Center, MO, USA.

Förderung

  • National Institute of Food and Agriculture
  • US Department of Agriculture
  • National Science Foundation

Zitieren

APA

Ccanccapa-Cartagena, A., Gopakumar, A. N., & Salehi, M. (2025). A straightforward Py-GC/MS methodology for quantification of microplastics in tap water. MethodsX, 14, 103173. https://doi.org/10.1016/j.mex.2025.103173

Vancouver

Ccanccapa-Cartagena A, Gopakumar AN, Salehi M. A straightforward Py-GC/MS methodology for quantification of microplastics in tap water. MethodsX. 2025;14:103173. doi:10.1016/j.mex.2025.103173

BibTeX
@article{CcanccapaCartagena2025,
  author = {Ccanccapa-Cartagena, Alexander and Gopakumar, Anandu Nair and Salehi, Maryam},
  title = {A straightforward Py-GC/MS methodology for quantification of microplastics in tap water},
  journal = {MethodsX},
  year = {2025},
  volume = {14},
  pages = {103173},
  doi = {10.1016/j.mex.2025.103173}
}
Kostenlos starten →