EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency

Sudesh Sivarasu, Ntokozo Magubane, Chibuike Mbanefo, Malebogo Ngoepe

Medical Engineering & Physics · 2025

DOI: 10.1016/j.medengphy.2025.104407 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Engineering & Physics, 2025. Verfasst von Sudesh Sivarasu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Biomedical Engineering, Department of Human Biology, Faculty of Health Science, University of Cape Town 7925, South Africa. Hauptthemen laut MEDLINE: Hydrodynamics, Mechanical Phenomena. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universityof CapeTown, National Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The usability and versatility of autoinjectors in managing chronic and autoimmune diseases have made them increasingly attractive in medicine. However, investigations into autoinjector designs require an understanding of the kinematic properties and fluid behaviour during injection. To optimise injection efficiency, this study develops a mathematical and computational fluid dynamics (CFD) model of an IM autoinjector by investigating the effects of viscosity, needle length, needle diameter, and medication volume on the injection process. The model was verified and validated using a comparator experiment and optimised using a parameter sensitivity analysis. The mathematical model results show plunger displacement increases linearly in low viscous fluids (v 20 cP) reduce injectability and increase syringeability. Needle gauges below 20 exhibited constant dynamic pressure and negligible shear stress, while gauges between 20 and 25 showed higher shear stress and pressure variability. Longer needles and larger medication volumes increase dynamic pressure and shear stress, prolonging injection time. The mathematical and CFD models matched experimental measurements within a 1.1 % and 4.8 % margin of error, respectively. These findings inform the design of efficient autoinjectors, enhancing drug delivery, patient comfort, and compliance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrodynamicsMechanical PhenomenaBiomechanical PhenomenaEquipment DesignInjections, IntramuscularViscosityNeedlesHumansPressure

Stichwörter der Autor:innen

AutoinjectorComputational fluid dynamicsInjection efficiencyNeedle gaugePlunger displacementShear stressViscosity

Autor:innen und Institutionen

  • Division of Biomedical Engineering, Department of Human Biology, Faculty of Health Science, University of Cape Town 7925, South Africa.
  • Division of Biomedical Engineering, Department of Human Biology, Faculty of Health Science, University of Cape Town 7925, South Africa. Electronic address: Chibuike.mbanefo@uct.ac.za.
  • Department of Mechanical Engineering, University of Cape Town, 7701, South Africa; Centre for Research in Computational and Applied Mechanics (CERECAM), University of Cape Town, 7701, South Africa.

Förderung

  • Universityof CapeTown
  • National Research Foundation

Zitieren

APA

Sivarasu, S., Magubane, N., Mbanefo, C., & Ngoepe, M. (2025). A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2025.104407

Vancouver

Sivarasu S, Magubane N, Mbanefo C, Ngoepe M. A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency. Medical Engineering & Physics. 2025. doi:10.1016/j.medengphy.2025.104407

BibTeX
@article{Sivarasu2025,
  author = {Sivarasu, Sudesh and Magubane, Ntokozo and Mbanefo, Chibuike and Ngoepe, Malebogo},
  title = {A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency},
  journal = {Medical Engineering & Physics},
  year = {2025},
  doi = {10.1016/j.medengphy.2025.104407}
}
Kostenlos starten →