Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques
Medical Engineering & Physics · 2024
DOI: 10.1016/j.medengphy.2024.104252 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Medical Engineering & Physics, 2024. Verfasst von Katee N Perez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, University of Utah, UT, United States. Electronic address: katee.perez@utah.edu. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Weight-Bearing, Cadaver. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
This study aimed to validate the use of weightbearing computed tomography against conventional computed tomography and against bead tracking for markerless tracking of key foot and ankle bones. A left cadaveric limb was implanted with tantalum beads and underwent conventional computed tomography and weightbearing computed tomography scanning, followed by biplane fluoroscopy motion capture to simulate gait. Bone models from conventional computed tomography and weightbearing computed tomography were compared for surface differences and kinematic analysis across six joints. Results showed the average surface distance difference across all weightbearing computed tomography bones were a fraction of a voxel smaller than the conventional computed tomography bones on average. Additionally, the absolute mean and standard deviation of the mean angle differences across all trials, joints, and planes was less than one degree. Weightbearing computed tomography demonstrated comparable accuracy to conventional computed tomography and to bead tracking, confirming its utility in dynamic biomechanical analysis with reduced radiation exposure and the ability to image under load. This validation supports weightbearing computed tomography's broader adoption in clinical and research settings for enhanced foot and ankle diagnostics and treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, University of Utah, UT, United States. Electronic address: katee.perez@utah.edu.
- Department of Orthopaedics, University of Utah, UT, United States. Electronic address: andrew.c.peterson@utah.edu.
- Department of Orthopaedics, University of Utah, UT, United States. Electronic address: rich.lisonbee@utah.edu.
- C-Motion Inc., Germantown, MD, United States. Electronic address: peter@c-motion.com.
- Department of Orthopaedics, University of Utah, UT, United States; Department of Biomedical Engineering, University of Utah, UT, United States. Electronic address: amy.lenz@utah.edu.
Zitieren
APA
Perez, K. N., Peterson, A. C., Lisonbee, R. J., Loan, J. P., & Lenz, A. L. (2024). Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2024.104252
Vancouver
Perez KN, Peterson AC, Lisonbee RJ, Loan JP, Lenz AL. Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques. Medical Engineering & Physics. 2024. doi:10.1016/j.medengphy.2024.104252
BibTeX
@article{Perez2024,
author = {Perez, Katee N and Peterson, Andrew C and Lisonbee, Rich J and Loan, J Peter and Lenz, Amy L},
title = {Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques},
journal = {Medical Engineering & Physics},
year = {2024},
doi = {10.1016/j.medengphy.2024.104252}
}
EUVIMED