Effects of minimum monitor unit per dynamic control point on intensity‐modulated radiotherapy planning for nasopharyngeal carcinoma: A retrospective study
Medical Dosimetry · 2025
DOI: 10.1016/j.meddos.2024.09.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Dosimetry, 2025. Verfasst von Xiwei Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Technology Application, China Institute of Atomic Energy, Beijing, 102413, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Nasopharyngeal Carcinoma, Nasopharyngeal Neoplasms. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
The present study aimed to improve the dose distribution of radiotherapy planning for nasopharyngeal carcinoma (NPC) by comparing the effects of various minimum monitor units (MUs) per dynamic control point (MMCP) values on the quality and execution efficiency of dynamic intensity-modulated radiotherapy (IMRT) planning. Thirty-four clinically implemented dynamic IMRT plans for patients with NPC were retrospectively selected. In total, 170 plans were obtained by modifying only the MMCP values (set as 1, 3, 5, 7, and 9) in the treatment planning system's (TPS) optimization parameters. These plans were divided into 5 groups. Analyzing the effects of MMCP on the target and organ dose at risk (OAR), also the execution efficiency of the treatment plan in each group and using a quality score system, we conducted an objective quantitative study of the dose distribution and execution efficiency. The target dose evaluation indicators (target coverage (TC), homogeneity index (HI), and conformity index (CI)) of all IMRT plans showed a trend of variation with an increase in MMCP values, and the difference was statistically significant when MMCP values were 5, 7, 9, and 1 (p 0.05). With an increase in MMCP, the average number of MUs per segment significantly increased (p < 0.01). The groups based on MMCP values of 1, 3, 5, 7, and 9 received quality score system of 1.188, 1.180, 1.171, 0.987, and 1.184, respectively, with the MMCP7 group achieving the lowest score, indicating that this plan had the highest overall quality. The MMCP value for dynamic IMRT planning in the Monaco TPS for patients with NPC should be set to 7 to achieve fewer segments, the best execution efficiency without significantly deteriorating the target and OAR dose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nuclear Technology Application, China Institute of Atomic Energy, Beijing, 102413, China.
- Fuzhou First General Hospital Affiliated with Fujian Medical University, Fuzhou, 350009, China.
- Center of Radiation Oncology, Ganzhou Cancer Hospital, Ganzhou, 341000, Jiangxi Province, China.
- Southern Medical University Hospital of Integrated Traditional Chinese and Western Medicine, Southern Medical University, Guangzhou, 510000, China.
- The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China.
- Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou, 510280, China.
Zitieren
APA
Chen, X., Cheng, Y., Wu, W., He, Y., Zhang, Y., Han, L., He, G., & Li, Z. (2025). Effects of minimum monitor unit per dynamic control point on intensity‐modulated radiotherapy planning for nasopharyngeal carcinoma: A retrospective study. Medical Dosimetry. https://doi.org/10.1016/j.meddos.2024.09.003
Vancouver
Chen X, Cheng Y, Wu W, He Y, Zhang Y, Han L, et al. Effects of minimum monitor unit per dynamic control point on intensity‐modulated radiotherapy planning for nasopharyngeal carcinoma: A retrospective study. Medical Dosimetry. 2025. doi:10.1016/j.meddos.2024.09.003
BibTeX
@article{Chen2025,
author = {Chen, Xiwei and Cheng, Yuan and Wu, Weiwei and He, Yadi and Zhang, Yangming and Han, Liwan and He, Gaokui and Li, Zhenghuan},
title = {Effects of minimum monitor unit per dynamic control point on intensity‐modulated radiotherapy planning for nasopharyngeal carcinoma: A retrospective study},
journal = {Medical Dosimetry},
year = {2025},
doi = {10.1016/j.meddos.2024.09.003}
}
EUVIMED